Influence of coronary occlusion during PTCA on end-systolic and end-diastolic pressure-volume relations in humans.

Author:

Kass D A1,Midei M1,Brinker J1,Maughan W L1

Affiliation:

1. Division of Cardiology, Johns Hopkins Medical Institutions, Baltimore, Maryland 21205.

Abstract

The influence of acute coronary occlusion on systolic and diastolic left ventricular pressure-volume relations was studied in 10 patients undergoing percutaneous transluminal coronary angioplasty (PTCA). Pressure-volume relations were obtained by conductance catheter and micromanometer techniques and with volume load altered by transient inferior vena caval occlusion. End-systolic and end-diastolic pressure-volume relations were obtained at baseline, during 60-90 seconds of ischemia, and at return to baseline after angioplasty balloon deflation. Coronary occlusion significantly altered systolic and diastolic chamber function. Systolic dysfunction was characterized by a reproducible rightward shift of the end-systolic pressure-volume relation (+25.4 +/- 18.4 ml) that was greater for proximal left anterior descending and circumflex coronary artery occlusions (+41 ml) than for distal or right coronary artery occlusions (+15.4 ml, p less than 0.05). Occlusion also lowered chamber systolic function indexes, such as the end-systolic pressure-volume relation slope (from 4.2 to 2.8 mm Hg/ml) and preload recruitable stroke work (from 97 to 78.6 mm Hg). All systolic (and diastolic) changes were resolved with successful angioplasty. Diastolic abnormalities during angioplasty were characterized by prolonged pressure relaxation and an upward shift of the resting diastolic pressure-volume data and by an apparent increase in chamber elastic stiffness. However, when end-diastolic data from multiple beats during inferior vena caval occlusion were compared, control and ischemic end-diastolic pressure-volume relations displayed little or no difference. Thus, elevations in resting diastolic pressure-volume relations and apparent increase in chamber elastic stiffness during coronary occlusion in humans appear dominated by altered right ventricular or pericardial loading. These data indicate that pressure-volume analysis is useful in assessing the functional significance of coronary lesions and reperfusion.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 121 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3