Ambulatory follow-up of aortic dissection by transesophageal two-dimensional and color-coded Doppler echocardiography.

Author:

Mohr-Kahaly S1,Erbel R1,Rennollet H1,Wittlich N1,Drexler M1,Oelert H1,Meyer J1

Affiliation:

1. II. Medical Clinic, Johannes Gutenberg University Mainz, FRG.

Abstract

Follow-up of 18 patients with aortic dissection (five with type I, one with type II, 11 with type III dissection according to DeBakey) by transesophageal, two-dimensional and color-coded Doppler echocardiography showed a persistence of the false lumen in five of seven patients (71%) after surgery and in nine of 11 patients (82%) after medical therapy. In two patients treated with surgery, the dissected part of the aorta had been resected, whereas in two patients treated medically, a progressive and complete obliteration of the false lumen was observed. In the false lumen, thrombus formation was absent in four, localized in four, and progressive in six patients. Flow within the false lumen could be registered in 14 patients, and two distinct flow patterns were differentiated (laminar biphasic flow or slowly circulating flow). Persisting intimal tears were visualized by two-dimensional echocardiography in four patients, whereas color-coded Doppler showed an additional one to three intimal tears in the descending aorta in 10 patients. Flow across these intimal tears was biphasic in 75% of patients; that is, systolic flow was directed from the true to the false lumen with diastolic flow reversal. Unidirectional flow was detected in 25% of the communications, directed in 20% from the true to the false lumen, serving as an entry only and in one (5%) as reentry only. Additional information concerning complications like extension of the dissection (one of 18 patients), localized dilatation of the regurgitation (three of 18 patients) were detected by this method. Concerning the morphologic findings and the detection of flow characteristics, the transesophageal approach was superior to conventional echocardiography especially in the descending thoracic aorta. Thus, transesophageal two-dimensional and color-coded Doppler echocardiography seems to be an ideal method not only for the easy detection of aortic dissection but also for follow-up.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3