Evaluation of standard and active compression-decompression CPR in an acute human model of ventricular fibrillation.

Author:

Shultz J J1,Coffeen P1,Sweeney M1,Detloff B1,Kehler C1,Pineda E1,Yakshe P1,Adler S W1,Chang M1,Lurie K G1

Affiliation:

1. University of Minnesota, Minneapolis.

Abstract

BACKGROUND The mechanisms that underlie cardiopulmonary resuscitation (CPR) in humans remain controversial and difficult to study. This report describes a new human model to evaluate CPR during the first 1 to 2 minutes after the onset of ventricular fibrillation (VF). With this model, standard CPR was compared with active compression-decompression (ACD) CPR, a method that uses a handheld suction device to actively compress and actively decompress the chest. METHODS AND RESULTS During routine inductions of VF as part of a transvenous lead cardioverter/defibrillator implantation procedure, CPR was performed in 21 patients if the first defibrillation shock failed and until a successful rescue shock was delivered. Compressions during CPR were performed according to American Heart Association guidelines. For ACD CPR, decompression was performed with up to -30 lbs. Radial arterial and right atrial pressures were measured in all patients. Esophageal pressures, intratracheal pressures, or minute ventilation was measured in the last 13 patients. Application of both CPR techniques increased arterial and right atrial pressures. The mean coronary perfusion pressure was increased throughout the entire CPR cycle with ACD CPR (compression, 21.5 +/- 9.0 mm Hg; decompression, 21.9 +/- 8.7 mm Hg) compared with standard CPR (compression, 17.9 +/- 8.2 mm Hg; decompression, 18.5 +/- 6.9 mm Hg; P < .02 and P < .02, respectively). Ventilation per compression-decompression cycle was 97.3 +/- 65.6 mL with standard CPR and 168.4 +/- 68.6 mL with ACD CPR (n = 7, P < .001). Negative inspiratory pressure was -0.8 +/- 4.8 mm Hg with standard CPR and -11.4 +/- 6.3 mm Hg with ACD CPR (n = 6, P < .04). CONCLUSIONS Patients undergoing multiple inductions of VF during cardioverter/defibrillator implantation with transvenous leads provide a well-controlled and reproducible model to study the mechanisms of CPR. Using this model, ACD CPR significantly increased arterial blood pressure, coronary perfusion pressure, minute ventilation, and negative inspiratory pressure compared with standard CPR.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3