Abstract

Abstract Background Ventilation during cardiopulmonary resuscitation (CPR) has long been a part of the standard treatment during cardiac arrests. Ventilation is usually given either during continuous chest compressions (CCC) or during a short pause after every 30 chest compressions (30:2). There is limited knowledge of how ventilation is delivered if it effects the hemodynamics and if it plays a role in the occurrence of lung injuries. The aim of this study was to compare ventilation parameters, hemodynamics, blood gases and lung injuries during experimental CPR given with CCC and 30:2 in a porcine model. Methods Sixteen pigs weighing approximately 33 kg were randomized to either receive CPR with CCC or 30:2. Ventricular fibrillation was induced by passing an electrical current through the heart. CPR was started after 3 min and given for 20 min. Chest compressions were provided mechanically with a chest compression device and ventilations were delivered manually with a self-inflating bag and 12 l/min of oxygen. During the experiment, ventilation parameters and hemodynamics were sampled continuously, and arterial blood gases were taken every five minutes. After euthanasia and cessation of CPR, the lungs and heart were removed in block and visually examined followed by sampling of lung tissue which were examined using microscopy. Results In the CCC group and the 30:2 group, peak inspiratory pressure (PIP) was 58.6 and 35.1 cmH2O (p < 0.001), minute volume (MV) 2189.6 and 1267.1 ml (p < 0.001), peak expired carbon dioxide (PECO2) 28.6 and 39.4 mmHg (p = 0.020), partial pressure of carbon dioxide (PaCO2) 50.2 and 61.1 mmHg (p = 0.013) and pH 7.3 and 7.2 (p = 0.029), respectively. Central venous pressure (CVP) decreased more over time in the 30:2 group (p = 0.023). All lungs were injured, but there were no differences between the groups. Conclusions Ventilation during CCC resulted in a higher PIP, MV and pH and lower PECO2 and PaCO2, showing that ventilation mode during CPR can affect ventilation parameters and blood gases.

Funder

Jolife AB/Stryker, Lund Sweden

Uppsala University

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3