Ultrasonic energy. Effects on vascular function and integrity.

Author:

Fischell T A1,Abbas M A1,Grant G W1,Siegel R J1

Affiliation:

1. Division of Cardiovascular Medicine, Stanford University Medical Center, CA 94305.

Abstract

BACKGROUND Ultrasonic energy transmitted via flexible wire probes provides a new means of ablating atherosclerotic plaque. We studied the effects of ultrasonic energy (20 kHz) delivered via a ball-tipped wire probe on arterial vasomotor behavior in rabbit thoracic aortas in a perfused whole-vessel model. METHODS AND RESULTS After precontraction with phenylephrine (10(-5) M) or KCl (60 mM), the effects of ultrasonic energy (0.7-5.5 W x 60 seconds, 42-330 J) on arterial vasomotor behavior were measured using long-axis ultrasonic vessel imaging of the proximal (ultrasonic probe-treated) and distal (untreated) control segments. The efficacy of plaque ablation at these same probe-tip power outputs was evaluated in atherosclerotic, human cadaver iliofemoral arteries. Ultrasonic energy caused dose (energy)-dependent relaxation in rabbit aortas after precontraction with phenylephrine in arteries with endothelium (n = 8) and without endothelium (n = 8) (p less than 0.001 versus ultrasound treated at power outputs of 2.9 and 5.5 W). There was no difference in the relaxation dose responses between endothelialized and endothelially denuded segments (p = NS). Ultrasonic energy also caused significant relaxation (67 +/- 8%) after voltage-dependent precontraction with 60 mM KCl. Temperature measurements revealed less than 1 degrees C warming of the vessel wall during as long as 2 minutes of treatment at a power output of 5.5 W. Pathological examination showed no smooth muscle injury at (moderate) power outputs that caused arterial relaxation. At probe-tip power outputs of 2.9-5.5 W, ultrasonic energy recanalized two of two totally occluded cadaveric iliofemoral vessel segments. The ultrasonic ablation catheter was also demonstrated to cause arterial relaxation in a recanalized canine femoral artery in vivo. CONCLUSIONS Ultrasonic energy delivered via a flexible-wire probe produces dose-dependent, endothelium-independent smooth muscle relaxation capable of reversing both receptor-mediated and voltage-dependent vasoconstriction in vitro. At moderate power outputs, this relaxation response does not appear to be due to thermal effects or irreversible smooth muscle cell injury. This vasorelaxant effect of ultrasonic energy is also apparent in vivo, at doses that effectively ablate atherosclerotic plaque, and may improve the safety of arterial recanalization using ultrasonic energy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 77 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3