Ultrasonic plaque ablation. A new method for recanalization of partially or totally occluded arteries.

Author:

Siegel R J1,Fishbein M C1,Forrester J1,Moore K1,DeCastro E1,Daykhovsky L1,DonMichael T A1

Affiliation:

1. Division of Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA 90048.

Abstract

The potential application of ultrasonic energy for ablation of atherosclerotic plaques was studied in human atherosclerotic arteries with continuous and pulsed delivery of energy. With a prototype ultrasonic wire probe (n = 79 segments), there was gross reduction in vascular lesions as well as microscopic disruption of fibrous and calcified plaques. Normal portions of vessels appeared unaffected by the application of ultrasound. The prototype ultrasonic wire catheter ablated calcific deposits in less than 10 seconds. With this probe, all 26 complete atherosclerotic occlusions 0.5-5 cm in length were recanalized irrespective of the presence of calcium. Twenty-four of the segments were reopened in less than 20 seconds. By light microscopy, the site of plaque ablation was smooth, concave, and conformed to the shape of the probe tip. In 17 samples, there was evidence of thermal injury, and in six of the 79 samples studied with the prototype probe, there was vascular perforation. No vascular perforation occurred without thermal damage, when pulsed (rather than continuous) ultrasonic energy was used (n = 40) or when the duration of application was less than 30 seconds, with power output less than 25 W and with the probe oriented parallel to the wall (n = 26). Thus, by modifying the duration, mode, and magnitude of the ultrasonic power output, thermal injury and vascular perforation may be avoided. In vivo intra-arterial ultrasonic angioplasty of a canine chronic femoral fibrocellular occlusion was also performed. A preliminary in vivo study demonstrated feasibility of the percutaneous application of intra-arterial ultrasonic recanalization. Thus, ultrasonic energy appears to have potential as a method for ablation of occlusive atherosclerotic plaque.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 100 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3