Favorable Trend of Implantable Cardioverter‐Defibrillator Service Life in a Large Single‐Nation Population: Insights From 10‐Year Analysis of the Italian Implantable Cardioverter‐Defibrillator Registry

Author:

Poli Stefano1,Boriani Giuseppe2,Zecchin Massimo3,Facchin Domenico1,Gasparini Maurizio4,Landolina Maurizio5,Ricci Renato Pietro6,Lanera Corrado7,Gregori Dario7,Proclemer Alessandro1

Affiliation:

1. Cardiology Division Azienda Sanitaria Universitaria Integrata di Udine and IRCAB Foundation Udine Italy

2. Cardiology Division Department of Biomedical, Metabolic and Neural Sciences University of Modena and Reggio Emilia Policlinico di Modena Modena Italy

3. Cardiovascular Department Azienda Sanitaria Universitaria Integrata di Trieste Trieste Italy

4. Electrophysiology and Pacing Unit Humanitas Research Hospital IRCCS Rozzano Italy

5. Cardiology Department Ospedale Maggiore Crema Italy

6. CCU‐Cardiology Department Presidio Ospedaliero San Filippo Neri Roma Italy

7. Biostatistic Unit Department of Cardiac Thoracic Vascular Sciences and Public Health University of Padova Italy

Abstract

Background Implantable cardioverter‐defibrillators ( ICDs ) are widely employed for the prevention of sudden cardiac death. Despite technological improvements, patients often need to undergo generator replacement, which entails the risk of periprocedural complications. Our aim was to estimate the service life of ICD s over a 10‐year interval and to assess the main causes of replacement on the basis of data from the National ICD Registry of the Italian Society of Arrhythmology and Cardiac Pacing (AIAC). Methods and Results The registry includes data from over 400 hospitals in Italy. We included all patients who underwent device replacement from calendar years 2007 to 2016. The median service life of the ICD s and its trend over the years was estimated across the 3 types of devices (single‐chamber, dual‐chamber, cardiac resynchronization therapy defibrillator) and the indication to implantation. The causes of replacement were also analyzed. We included 29 158 records from 27 676 patients (80.9% men; mean age at device replacement 65.8±12.0 years). The median service life was 57.3 months (interquartile range 27.8 months). Over the years, service life showed an increasing trend. The majority of patients underwent elective replacement because of battery end of life, and over the years there was a significant reduction of replacement for recalls, erosion/infections, and cardiac resynchronization therapy upgrading. Conclusions Our data from a large single‐nation population showed that the trend of ICD service life, independently from ICD type, indication, and settings, significantly improved over time. Moreover, there was a striking reduction of interventions for upgrading and infection/erosion. This favorable trend has important clinical, organizational, and financial implications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3