Cardiovascular Risk in Hypertension in Relation to Achieved Blood Pressure Using Automated Office Blood Pressure Measurement

Author:

Myers Martin G.1,Kaczorowski Janusz1,Dolovich Lisa1,Tu Karen1,Paterson J. Michael1

Affiliation:

1. From the Schulich Heart Program, Sunnybrook Health Sciences Centre (M.G.M.), Institute for Clinical Evaluative Sciences (K.T., J.M.P.), University Health Network–Toronto Western Hospital Family Health Team (K.T.), Department of Medicine (M.G.M.), Department of Family and Community Medicine (K.T.), and Institute of Health Policy, Management and Evaluation (K.T., J.M.P.), University of Toronto, Toronto, Canada; the Department of Family and Emergency Medicine, Université de Montréal, and CRCHUM,...

Abstract

The SPRINT (Systolic Blood Pressure Intervention Trial) reported that some older, higher risk patients might benefit from a target systolic blood pressure (BP) of <120 versus <140 mm Hg. However, it is not yet known how the BP target and measurement methods used in SPRINT relate to cardiovascular outcomes in real-world practice. SPRINT used the automated office BP technique, which requires the patient to be resting quietly and alone, with multiple readings being recorded automatically using an electronic oscillometric sphygmomanometer. We studied the relationship between achieved automated office BP at baseline and cardiovascular events in 6183 community-dwelling residents of Ontario aged ≥66 years who were receiving antihypertensive therapy and followed for a mean of 4.6 years. Adjusted hazard ratios (95% confidence intervals) were computed for 10 mm Hg increments in achieved automated office BP at baseline using Cox proportional hazards regression and the BP category with the lowest event rate as the reference category. Based on 904 fatal and nonfatal cardiovascular events, the nadir of cardiovascular events was at the systolic pressure category of 110 to 119 mm Hg, which was lower than the next highest category of 120 to 129 mm Hg (hazard ratio 1.30 [1.01, 1.66]). The hazard ratio for diastolic pressure was relatively unchanged above 60 mm Hg. Pulse pressure exhibited an increase in hazard ratio (1.33 [1.02, 1.72]) at ≥80 mm Hg. These results using automated office BP measurement in a usual treatment setting extend the finding in SPRINT of an optimum target systolic BP of <120 mm Hg to routine clinical practice.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3