Hypo‐Attenuated Leaflet Thickening and Reduced Leaflet Motion in Sutureless Bioprosthetic Aortic Valves

Author:

Dalén Magnus12,Sartipy Ulrik12,Cederlund Kerstin34,Franco‐Cereceda Anders12,Svensson Anders34,Themudo Raquel35,Svenarud Peter12,Bacsovics Brolin Elin34

Affiliation:

1. Department of Cardiothoracic Surgery and Anesthesiology, Karolinska University Hospital, Stockholm, Sweden

2. Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden

3. Department of Radiology Huddinge, Karolinska University Hospital, Stockholm, Sweden

4. Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden

5. Department of Clinical Physiology, Karolinska Institutet, Stockholm, Sweden

Abstract

Background The prevalence of hypo‐attenuated leaflet thickening ( HALT ) and reduced leaflet motion ( RLM ) is unknown in surgically implanted bioprostheses because systematic investigation of HALT and/or RLM is limited to a few catheter‐based valves. The aim of this study was to investigate the prevalence of HALT and RLM by cardiac computed tomography in patients who underwent surgical aortic valve replacement and received a Perceval sutureless aortic valve bioprosthesis. Methods and Results This was a single‐center prospective observational study that included 47 patients (83.5% of the total number of implantations) who underwent surgical aortic valve replacement with implantation of the Perceval sutureless bioprosthesis (LivaNova PLC, London, UK) at Karolinska University Hospital in Stockholm, Sweden from 2012 to 2016 and were studied by cardiac computed tomography. Cardiac computed tomography was performed at a median of 491 days (range 36–1247 days) postoperatively. HALT was found in 18 (38%) patients and RLM in 13 (28%) patients. All patients with RLM had HALT . Among patients with HALT , 5 out of 18 patients (28%) were treated with anticoagulation (warfarin or any novel oral anticoagulant) at the time of cardiac computed tomography. Among patients with RLM , 3 out of 13 patients (23%) were treated with anticoagulation. Conclusions HALT and RLM were prevalent in the surgically implanted Perceval sutureless aortic valve bioprosthesis. Both HALT and RLM were found in patients with ongoing anticoagulation treatment. Whether these findings are associated with adverse events needs further study. Clinical Trial Registration URL : http://www.clinicaltrials.gov . Unique identifier: NCT 02671474.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3