Lower Expression of Neutrophil Adhesion Molecule Indicates Less Vessel Wall Injury and Might Explain Lower Restenosis Rate After Cutting Balloon Angioplasty

Author:

Inoue Teruo1,Sakai Yoshihiko1,Hoshi Kazuhiro1,Yaguchi Isao1,Fujito Tsuneo1,Morooka Shigenori1

Affiliation:

1. From the Department of Cardiology, Koshigaya Hospital, Dokkyo University School of Medicine, Saitama, Japan.

Abstract

Background —The Cutting Balloon is a novel dilatation catheter for coronary angioplasty (InterVentional Technologies Inc). It produces longitudinal, microsurgical incisions in the vessel wall before the actual dilatation. It is assumed that these controlled surgical incisions relieve hoop stress and reduce vessel wall injury and eventually restenosis. However, no clinical indicator to support the theory of reduced injury has been described. Certain clusters of differentiation (eg, CD11, CD18 on the leukocytes) are implicated in leukocyte adhesion, increased permeability, and opsonization. Therefore, they might serve as clinical indicators of the injury level of the vessels after angioplasty. Methods and Results —We randomly selected 64 patients with isolated left anterior descending coronary artery disease for either Cutting Balloon angioplasty or conventional balloon angioplasty. The expression of CD18 and CD11b on the surface of neutrophils was determined by flow cytometric analysis. Serum levels of soluble intercellular adhesion molecule-1 (sICAM-1) were also measured. The expression of both the CD18 and CD11b in the coronary sinus blood gradually increased and reached its maximum at 48 hours after angioplasty. The sICAM-1 levels in the coronary sinus serum also increased after angioplasty. Percentage increases of CD18 and CD11b expression and the increase of the sICAM-1 levels at 48 hours after angioplasty (as ratios to baseline values before angioplasty) were less in the Cutting Balloon angioplasty group than in the conventional balloon angioplasty group (CD18, 1.10±0.05 versus 1.31±0.05, P <0.05; CD11b, 1.23±0.06 versus 1.72±0.10, P <0.001; sICAM-1, 1.12±0.05 versus 1.25±0.02, P <0.05). In all patients, the late lumen loss at follow-up angiogram positively correlated with the increased levels of CD11b ( R =0.59, P <0.001) and sICAM-1 ( R =0.38, P <0.05) at 48 hours after angioplasty. Conclusions —Balloon angioplasty upregulated Mac-1 (CD11b/CD18) on the surface of the neutrophils and increased sICAM-1 levels in association with late loss increase. These changes were significantly smaller in the Cutting Balloon angioplasty group than in the conventional balloon angioplasty group. This suggests that Cutting Balloon angioplasty may produce less vessel wall injury and, consequently, less neutrophil activation, which may account for the lower rate of restenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference40 articles.

1. Cutting balloon: A novel approach to percutaneous angioplasty

2. Coronary Artery Incision and Dilation

3. Martinez D Goicolea J Alfonzo F Perez M Hernandez R Fernandez-Ortiz A Segovia J Banuelos C Macaya C. Intravascular ultrasound findings after cutting balloon angioplasty. Eur Heart J . 1996;17(suppl):188. Abstract.

4. Cooperative interactions of LFA-1 and Mac-1 with intercellular adhesion molecule-1 in facilitating adherence and transendothelial migration of human neutrophils in vitro.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3