Canadian Trial of Physiological Pacing

Author:

Kerr Charles R.1,Connolly Stuart J.1,Abdollah Hoshiar1,Roberts Robin S.1,Gent Michael1,Yusuf Salim1,Gillis Anne M.1,Tang Anthony S.L.1,Talajic Mario1,Klein George J.1,Newman David M.1

Affiliation:

1. From the Department of Medicine, University of British Columbia, Vancouver (C.R.K.); the Departments of Medicine (S.J.C., S.Y.) and Clinical Epidemiology and Biostatistics (R.S.R., M.G.), McMaster University, Hamilton, Ontario; the Department of Medicine, University of Calgary, Calgary, Alberta (A.M.G.); the Department of Medicine, University of Ottawa, Ottawa, Ontario (A.S.L.T.); the Institut de Cardiologie de Montreal, Montreal, Quebec (M.T.); the Department of Medicine, Queens University,...

Abstract

Background— The Canadian Trial of Physiological Pacing (CTOPP) reported that the risk of stroke or cardiovascular death was similar between patients receiving ventricular versus physiological pacemakers at the end of the original follow-up period of 3 years. However, the occurrence of atrial fibrillation was significantly less frequent with physiological pacemakers. To assess a potential delayed benefit of physiological pacing, follow-up of patients in this study was extended to 6 years. Methods and Results— A total of 1474 patients requiring a pacemaker for symptomatic bradycardia were randomized to receive ventricular and 1094 to physiological pacemakers. The primary outcome was stroke or cardiovascular death. The study was completed in July 1998, and follow-up was extended to July 2001. At a mean follow-up of 6.4 years, there was no difference between treatment groups in the primary outcome of cardiovascular death or stroke. There was no significant difference in total mortality or stroke between groups. There was a significantly lower rate of development of atrial fibrillation in the physiological group, with a relative risk reduction of 20.1% (CI, 5.4 to 32.5; P =0.009). Conclusions— The CTOPP extended study does not show a difference in cardiovascular death or stroke, or in total mortality, or in stroke between patients implanted with ventricular or physiological pacemakers over a mean follow-up of >6 years. However, there is a persistent significant reduction in the development of atrial fibrillation with physiological pacing.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 174 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3