Detection of left ventricular thrombus by two-dimensional echocardiography: sensitivity, specificity, and causes of uncertainty.

Author:

Stratton J R,Lighty G W,Pearlman A S,Ritchie J L

Abstract

To define the sensitivity, specificity and predictive accuracy of two-dimensional echocardiographic detection of left ventricular thrombus, the echocardiograms of 78 patients who had independent proof of the presence or absence of a left ventricular thrombus were interpreted without knowledge of any clinical data. The presence of thrombus was established by autopsy in four patients, by aneurysmectomy in three, and by indium-111 platelet imaging in 15; the absence of thrombus was proved by autopsy in 55 patients and by aneurysmectomy in one patient. The characteristics of true-positive and false-positive echocardiograms, interobserver variability, and clinical features associated with proved thrombus were also defined. The echocardiogram was positive for thrombus in 22 patients, equivocal in seven and negative in 49. For detection of thrombus, a positive or equivocal echocardiogram had a sensitivity of 95% (21 of 22), a specificity of 86% (48 of 56), and a predictive value of 72% (21 of 29); the predictive value of a negative study was 98% (48 of 49). Considering positive and equivocal studies separately, the predictive value of a positive study was 86% (19 of 22), while that of an equivocal study was only 29% (two of seven). Compared with patients who had no thrombus, patients with proved thrombus had a higher prevalence of electrocardiographic transmural anterior infarction (86% vs 13%), left ventricular aneurysm (73% vs 5%), and clinical systemic emboli (36% vs 7%) (all p less than 0.05). These clinical features help to identify a subset of patients most likely to have left ventricular thrombi who may benefit from echocardiography. Two-dimensional echocardiography is highly sensitive in detecting left ventricular thrombus, but false-positive studies are relatively common. Several echocardiographic criteria derived from analysis of the true and false positives in this study may help minimize diagnostic errors.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 291 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3