Author:
Wang Qingtao,Wang Bing,Zhang Xiaofeng,Zhong Xin,Chang Shuai,Yang Jinbo,Liang Jian,You Qiangqiang,Zhou Heng,Zhang Jiaqi
Abstract
Abstract
Background
Cardiac masses can encompass a variety of conditions, such as tumors, thrombi, vegetations, calcific lesions, and other rare diseases. Treatment and management of these types of cardiac masses differ considerably. Thus, accurately distinguishing among thrombi, benign tumors, and malignant tumors in the heart is of great importance. Contrast echocardiography (CE) has emerged as a promising technology. Although published guidelines suggest that CE can enhance image quality and assist in differentiating between benign and malignant lesions, most studies on CE diagnosis of cardiac masses are limited to case reports or retrospective/small-sample-sized prospective cohorts. This study aims to evaluate the diagnostic accuracy of CE in patients with suspected cardiac masses and address the insufficient evidence for differential diagnosis using CE.
Methods
Between April 2018 and July 2022, a prospective multicenter study was conducted, which included 145 consecutive patients suspected to have cardiac masses based on transthoracic echocardiography. All patients underwent CE examinations. The echocardiographic diagnosis relied on qualitative factors such as echogenicity, boundary, morphology of the base, mass perfusion, pericardial effusion, and motility as well as quantitative factors such as the area of the masses and the peak intensity ratio of the masses to adjacent myocardium (A1/A2).
Results
The final confirmed diagnoses were as follows: 2 patients had no cardiac mass, 4 patients had pseudomass, 43 patients had thrombus, 66 patients had benign tumors, and 30 patients had malignant tumors. The receiver operating characteristic (ROC) analysis indicated that an optimal A1/A2 cutoff value of 0.499 distinguished a cardiac tumor from a thrombus, with AUC, sensitivity, specificity, PPV, and NPV of 0.977, 97.9%, 90.7%, 95.9%, and 95.1%, respectively. The optimal A1/A2 cutoff value of 1.583 distinguished a cardiac tumor from a thrombus, with AUC, sensitivity, specificity, PPV, and NPV of 0.950, 93.3%, 93.9%, 87.5%, and 96.9%, respectively.
Conclusions
Combined with qualitative and quantitative analyses, CE has the potential to accurately differentiate among different types of cardiac masses.
Funder
Technology foundation of Xiangyang
Clinical Medical Technology Innovation Guidance Project of Hunan Provincial Department of Science and Technology
Key R&D foundation of Hubei Province and Science
Publisher
Springer Science and Business Media LLC