The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: an experimental study in open-chest dogs.

Author:

Fisher D C,Sahn D J,Friedman M J,Larson D,Valdes-Cruz L M,Horowitz S,Goldberg S J,Allen H D

Abstract

We measured aortic flow by two-dimensional Doppler echocardiography in an open-chest dog model to examine how variations in Doppler sample volume length and position influence aortic hemodynamic flow calculations. Fourteen dogs underwent right-heart bypass, in which venous return from the venae cavae drained by gravity to a reservoir. A variable-speed roller pump returned the blood to the pulmonary artery, fixing left-sided cardiac input and output. Echo Doppler measurements were performed using a 3.5 MHz transducer placed directly on the aortic arch to determine internal aortic cross-sectional area. The transducer was then directed to image the aortic arch for Doppler velocity measurements and the various sampling sites were investigated. Doppler cardiac output could then be determined for each of the various sample volumes over a range of known roller pump settings. Doppler velocity was analyzed using fast Fourier transform spectral analysis. Mean velocity over the cardiac cycle was obtained by planimetry of the area under the Doppler velocity curve with a minicomputer. Doppler-derived determinations of cardiac output achieved a correlation of r = 0.98-0.99 to values obtained by the roller pump over a range of cardiac outputs from 0.75-5 l/min. The standard error of the estimate was 0.21/min. In this laminar flow model, there was no difference between the predictive accuracy of any of the sampling sites over the range of roller pump flows. Our study shows that Doppler velocity measurements can be used to quantify aortic flow over a clinically useful range and that variations of sample length and position did not produce significant differences in calculated flows.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference14 articles.

1. Transcutaneous method of measuring Doppler cardiac output—I

2. Transcutaneous Doppler method of measuring cardiac output—II

3. Combined doppler and phased-array echocardiographic estimation of cardiac output.

4. Two-dimensional echo-range gated Doppler measurements of cardiac output and stroke volume in open chest dogs;Friedman MJ;Circulation,1980

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3