Effect of assessing velocity time integral at different locations across ventricular outflow tracts when calculating cardiac output in neonates

Author:

Huang Jane,Singh Yogen,Adie Mohammad,Noori Shahab,Ebrahimi Mahmood,Durand Manuel,Cayabyab Rowena,Ramanathan Rangasamy

Abstract

AbstractThis study aims to evaluate the effect of assessing velocity time integral at different locations across ventricular outflow tracts for calculating cardiac output (CO) in neonates. Velocity time integral (VTI) and CO were measured at 3 different locations across right and left ventricular outflow tracts using transthoracic echocardiography in healthy term neonates without any major congenital heart disease. ANOVA with Bonferroni correction was used to determine the differences between the VTI and CO sampled at these three locations. Forty-one neonates met inclusion criteria with mean gestational age of 38.6 ± 1 weeks and mean birth weight of 3155 ± 463 g. The median hours after birth when echocardiography was obtained was 23 h (range 11–68 h after birth). Left CO were 121 ± 30 mL/kg/min, 155 ± 38 mL/kg/min, and 176 ± 36 mL/kg/min measured below the valve, hinges of the valve, and tip of the valve, respectively. Right CO were 197 ± 73 mL/kg/min, 270 ± 83 mL/kg/min, and 329 ± 104 mL/kg/min measured below the valve, hinges of the valve, and tip of the valve, respectively. A statistically significant difference (P < 0.001) was found in the VTI and CO measured at the 3 different locations across both left and right ventricular outflow tracts.     Conclusions: There is a significant difference in measurements of VTI and CO depending on the location of Doppler gate sampling across the ventricular outflow tracts. Consistency and precision in Doppler gate location are essential for measuring VTI and calculating CO while assessing changes in hemodynamic status in critically ill infants. What is Known:• Targeted Neonatal Echocardiography is increasingly applied to measure cardiac output in critically ill neonates and serial assessments are performed to assess the trend in changes in cardiac output.• Noninvasive measurement using velocity time integral to calculate cardiac output is commonly performed. However, location of Doppler sample gate to measure ventricular outflow tract velocity time integral is not consistent. What is New:• Statistically significant changes in measured velocity time integral and cardiac output are noted based on the location of Doppler gate sampling.• To monitor the cardiac output for trending, it is important to be consistent with regards to the location of the Doppler sample gate to assess changes in cardiac output in critically ill newborns.

Funder

University of Southern California

Publisher

Springer Science and Business Media LLC

Subject

Pediatrics, Perinatology and Child Health

Reference22 articles.

1. Mertens L, Seri I, Marek J, Arlettaz R, Barker P, McNamara P, Moon-Grady AJ, Coon PD, Noori S, Simpson J, Lai WW Writing Group of the American Society of Echocardiography; European Association of Echocardiography; Association for European Pediatric Cardiologists (2011). Targeted neonatal echocardiography in the neonatal intensive care unit: practice guidelines and recommendations for training. Writing Group of the American Society of Echocardiography (ASE) in collaboration with the European Association of Echocardiography (EAE) and the Association for European Pediatric Cardiologists (AEPC). J Am Soc Echocardiogr: Official Publication of the American Society of Echocardiography 24(10):1057–1078. https://doi.org/10.1016/j.echo.2011.07.014

2. Wu TW, Noori S (2021) Recognition and management of neonatal hemodynamic compromise. Pediatr Neonatol 62(Suppl 1):S22–S29. https://doi.org/10.1016/j.pedneo.2020.12.007

3. Weisz DE, Jain A, Ting J, McNamara PJ, El-Khuffash A (2014) Non-invasive cardiac output monitoring in preterm infants undergoing patent ductus arteriosus ligation: a comparison with echocardiography. Neonatology 106(4):330–336. https://doi.org/10.1159/000365278

4. Boet A, Jourdain G, Demontoux S, De Luca D (2016) Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates. J Perinatol 36(9):748–752. https://doi.org/10.1038/jp.2016.65

5. Singh Y (2017) Echocardiographic evaluation of hemodynamics in neonates and children. Front Pediatr 5:201. https://doi.org/10.3389/fped.2017.00201

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3