Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.

Author:

Imholz B P1,Langewouters G J1,van Montfrans G A1,Parati G1,van Goudoever J1,Wesseling K H1,Wieling W1,Mancia G1

Affiliation:

1. Department of Internal Medicine, Academic Medical Centre, Amsterdam, The Netherlands.

Abstract

We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record signals on tape, to alternate measurements between fingers automatically each 30 minutes, and to correct for the hydrostatic height of the hand. We compared the pressure as measured by Portapres with contralateral intrabrachial pressure measured with an Oxford device. Results were obtained in eight volunteers and 16 hypertensive patients. Time lost due to artifact was about 10% for each device. In two patients a full 24-hour Oxford profile was not obtained. In the remaining 22 subjects finger systolic, diastolic, and mean pressures differed +1 (SD 9), -8 (6), and -10 (6) mm Hg, respectively, from intrabrachial pressure. These diastolic and mean pressure underestimations are similar to what was found earlier for Finapres, are typical for the technique, and are systematic. Avoiding brisk hand movements resulted in fewer waveform artifacts. The hand had to be kept covered to continue recording at low outside temperatures. Sleep was not disturbed by Portapres, and arterial pressure showed a marked fall during siesta and nighttime. There were no major limitations in behavior, and no discomfort that originated from continuous monitoring was reported. Measurements continued normally during physical exercise. Portapres provides for the first time continuous 24-hour, noninvasive ambulatory blood pressure waveform monitoring and offers real and obvious advantages over current noninvasive and invasive devices.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Reference29 articles.

1. O'Brien E Cox JP O'Malley K: Ambulatory blood pressure measurement in the evaluation of blood pressure lowering drugs (editorial review) / Hypertens 1989;7:243-247

2. Parati G Mutti E Ravogli A Trazzi S Villani A Mancia G: Advantages and disadvantages of non-invasive ambulatory blood pressure monitoring. / Hypertens 1990;8(suppl 6):S35-S38

3. Assessment of four ambulatory blood pressure monitors and measurements by clinicians versus intraarterial blood pressure at rest and during exercise

4. Experience with 24-hour ambulatory blood pressure monitoring in hypertension

5. Peniz J: Photoelectric measurement of blood pressure volume and flow in the finger in Albert A Vogt W Helbig W (eds): Digest of the 10th International Conference on Medical and Biological Engineering. Dresden FRG International Federation for Medical and Biological Engineering 1973 p 104