Parametric Study of Pulsed Field Ablation With Biphasic Waveforms in an In Vivo Heart Model: The Role of Frequency

Author:

García-Sánchez Tomás1ORCID,Amorós-Figueras Gerard2ORCID,Jorge Esther2,Campos María C.3ORCID,Maor Elad45ORCID,Guerra Jose M.2ORCID,Ivorra Antoni16ORCID

Affiliation:

1. Department of Information and Communication Technologies, Universitat Pompeu Fabra‚ Barcelona‚ Spain (T.G.-S.‚ A.I.).

2. Department of Cardiology, Hospital de la Santa Creu i Sant Pau, Institut d’Investigació Biomèdica-Sant Pau, CIBERCV, Universitat Autònoma de Barcelona, Spain (G.A.-F., E.J., J.M.G.).

3. Department of Pathology, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma, Barcelona, Spain (M.C.C.).

4. Chaim Sheba Medical Center, Tel Hashomer, Israel (E.M.).

5. Sackler School of Medicine, Tel Aviv University, Israel (E.M.).

6. Serra Húnter Fellow Programme (A.I.).

Abstract

Background: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. Methods: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260, and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. Results: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared with any of the biphasic protocols ( P <0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms versus 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. Conclusions: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3