Identification of Low-Voltage Areas: A Unipolar, Bipolar, and Omnipolar Perspective

Author:

van Schie Mathijs S.1ORCID,Kharbanda Rohit K.12ORCID,Houck Charlotte A.2,Lanters Eva A.H.1,Taverne Yannick J.H.J.2,Bogers Ad J.J.C.2ORCID,de Groot Natasja M.S.1ORCID

Affiliation:

1. Department of Cardiology (M.S.v.S., R.K.K., C.A.H., E.A.H.L., N.M.S.d.G.), Erasmus Medical Center, Rotterdam, the Netherlands.

2. Department of Cardiothoracic Surgery (R.K.K., C.A.H., Y.J.H.J.T., A.J.J.C.B.), Erasmus Medical Center, Rotterdam, the Netherlands.

Abstract

Background: Low-voltage areas (LVAs) are commonly considered surrogate markers for an arrhythmogenic substrate underlying tachyarrhythmias. It remains challenging to define a proper threshold to classify LVA, and it is unknown whether unipolar, bipolar, and the recently introduced omnipolar voltage mapping techniques are complementary or contradictory in classifying LVAs. Therefore, this study examined similarities and dissimilarities in unipolar, bipolar, and omnipolar voltage mapping and explored the relation between various types of voltages and conduction velocity (CV). Methods: Intraoperative epicardial mapping (interelectrode distance 2 mm, ±1900 sites) was performed during sinus rhythm in 21 patients (48±13 years, 9 male) with atrial volume overload. Cliques of 4 electrodes (2×2 mm) were used to calculate the maximal unipolar, bipolar, and omnipolar voltages and mean CV. Areas with maximal bipolar or omnipolar clique voltage ≤0.5 mV were defined as LVA. Results: The maximal unipolar clique voltage was not only larger than maximal bipolar clique voltage but also larger than maximal omnipolar clique voltage (7.08 [4.22–10.59] mV versus 5.27 [2.39–9.56] mV and 5.77 [2.58–10.52] mV, respectively, P <0.001). In addition, the largest bipolar clique voltage was on average 1.66 (range: 1.0–59.0) times larger to the corresponding perpendicular bipolar voltage pair. LVAs identified by a bipolar or omnipolar threshold corresponded to a broad spectrum of unipolar voltages and, although CV was generally decreased, still high CVs and large unipolar voltages were found in these LVAs. Conclusions: In patients with atrial volume overload, there were considerable discrepancies in the different types of LVAs. Additionally, the identification of LVAs was hampered by considerable directional differences in bipolar voltages. Even using directional independent omnipolar voltage to identify LVAs, high CVs and large unipolar voltages are present within these areas. Therefore, a combination of low unipolar and low omnipolar voltage may be more indicative of true LVAs.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3