Selection of Critical Isthmus in Scar-Related Atrial Tachycardia Using a New Automated Ultrahigh Resolution Mapping System

Author:

Laţcu Decebal Gabriel1,Bun Sok-Sithikun1,Viera Frédéric1,Delassi Tahar1,El Jamili Mohammed1,Al Amoura Alaa1,Saoudi Nadir1

Affiliation:

1. From the Centre Hospitalier Princesse Grace, Monaco.

Abstract

Background— Accurate activation mapping of reentrant scar-related atrial tachycardias (AT) allows efficient radiofrequency ablation by targeting the critical isthmus (CI). We aimed to assess the electrophysiological properties of CI channels during mapping with the IntellaMap Orion basket and the Rhythmia system. Methods and Results— We prospectively studied 33 AT (post– atrial fibrillation ablation or surgical mitral valve repair). The noise of bipolar electrogram (EGM) was systematically measured at 10 prespecified sites, as well as on a standard catheter and on the surface ECG. Bipolar EGM of CI regions were analyzed for amplitude, duration, and conduction velocity. The isthmus region to be targeted was chosen based solely on propagation. For each AT, 25 684±14 276 EGMs were automatically annotated. Noise of the Orion EGM was 0.011±0.004 mV, lower than that of a standard catheter (0.016±0.019) and surface ECG (0.02±0.01; P <0.05). For reentrant AT, within the CI, bipolar EGM amplitude (0.08±0.11 mV) and conduction velocity (0.27±0.19 m/s) were lower than those orthodromically before (0.62±0.93 mV; 1±0.49 m/s) and after (0.80±1.59 mV; 1±0.73 m/s) the isthmus ( P <0.001 for all). In 97% of AT, ablation at the CI resulted in AT termination. No complications occurred. Conclusions— This new automated ultrahigh resolution mapping system produces low noise and allows accurate diagnosis of AT circuits. CI on reentrant scar-related AT showed much lower EGM amplitude with a significantly slower conduction velocity than the surrounding parts of the circuit. Ablation of the areas of slow conduction resulted in a high acute success.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 100 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3