Automatic identification of ablation targets in persistent atrial fibrillation: Initial experience with a new mapping tool

Author:

Lațcu Decebal Gabriel1ORCID,Enache Bogdan12,Lerebours Chloe3,Milanese Sofia3,Benhenda Nazih1,Canepa Silvia3,Kingston Amanda3,Meo Marianna3,Saoudi Nadir1

Affiliation:

1. Departement of Cardiology Centre Hospitalier Princesse Grace Monaco Monaco

2. University of Medicine and Pharmacy Timişoara Timișoara Romania

3. Boston Scientific Corp. Cambridge Massachusetts USA

Abstract

AbstractIntroductionStrategies beyond pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) are debated. A novel mapping tool provides algorithmic detection of ablation targets based on electrogram (EGM) properties specific to stable localized rotational activations.MethodsThe mapping tool was used on 31 patients (20 de novo). The algorithm was used to optimize PVI line placement and guide additional ablations. Targets were detected by calculating local cycle length (L‐CL) and local spread of activation within that L‐CL (Duty Cycle; DC) for EGMs with consistent morphology and activation. At least two left atrial (LA) maps (pre‐PVI and post‐PVI) were acquired in atrial fibrillation (AF) in all patients (except those with AF termination during PVI). Extra‐pulmonary vein (PV) targets were compared between the two LA maps in each patient. Follow‐up included Holter monitoring every 3 months.ResultsPatients had a median of 3 extra‐PV drivers/targets. The majority (81%) were localized in the same areas between the two LA maps. All patients had progressive AF organization demonstrated by global activation slowing: histogram peak L‐CL increased from 162 to 171 ms (post‐PVI; p = .0003) than to 175 ms (posttarget ablation; p = .04). Moreover, L‐CL dispersion was reduced by ablation; in 50% their values tended to cluster around two dominant cycles. In de novo patients AF terminated to sinus rhythm or atrial tachycardia (AT) within 48 h postprocedure in 88% of cases, and at 18 months mean follow‐up recurrence occurred in only five (25%) patients (three persAF, two AT). There were no complications.ConclusionThe algorithmic detection of EGMs consistent with localized reentry during sequential mapping of persAF provided reproducible targets for ablation. This allowed personalized PVI and limited, highly‐selective, extra‐PV ablation. Results of this initial experience included progressive organization of AF with ablation and a low recurrence rate after a single procedure.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3