Affiliation:
1. From the Department of Cardiology, Cedars-Sinai Medical Center, and the Department of Medicine, University of California, Los Angeles, California.
Abstract
A technique was developed for measurement of blood flow in the coronary sinus in man by continuous thermodilution. For single determinations, 5% dextrose at room temperature is injected at a constant rate of 35 ml/min for a period of about 20 sec. In 14 subjects with normal coronary arteries the mean coronary sinus blood flow was 122 ± 25 ml/min (range, 83 to 159 ml/min). The blood flow computed per 100 g of left ventricle was 82 ± 16 ml/min, which is in the range of values obtained by nitrous oxide and coincidence counting methods. In 35 patients with arteriographically confirmed coronary artery disease the mean flow was similar (128 ± 20 ml/min; range, 92 to 167 ml/min).
A special catheter was used for simultaneous measurement of blood flow in the coronary sinus and great cardiac vein. In eight normal subjects the mean great cardiac vein flow was 68 ± 11 ml/min (range, 51 to 78 ml/min) or 65 ± 10% of the coronary sinus blood flow. The method allowed continuous measurement of flow over a period of several minutes and, for the first time, measurement of rapid changes in myocardial perfusion.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Reference33 articles.
1. DETERMINATION OF CARDIAC OUTPUT IN MAN BY A NEW METHOD BASED ON THERMODILUTION
2. Measurement of blood flow by local thermodilution;J Physiol (London),1964
3. A local thermodilution flowmeter for the measurement of venous blood flow in man;Med Biol Engin,1967
Cited by
1037 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献