Aortic Valve Reconstruction With Autologous Pericardium Versus a Bioprosthesis: The Ozaki Procedure in Perspective

Author:

Unai Shinya1ORCID,Ozaki Shigeyuki2ORCID,Johnston Douglas R.1,Saito Tomohiro2ORCID,Rajeswaran Jeevanantham3,Svensson Lars G.1ORCID,Blackstone Eugene H.13ORCID,Pettersson Gösta B.1

Affiliation:

1. Department of Thoracic and Cardiovascular Surgery Heart, Vascular, and Thoracic Institute Cleveland Clinic Cleveland OH

2. Department of Cardiovascular Surgery Toho University Ohashi Medical Center Tokyo Japan

3. Department of Quantitative Health Sciences Lerner Research Institute Cleveland Clinic Cleveland OH

Abstract

Background We assessed the Ozaki procedure, aortic valve reconstruction using autologous pericardium, with respect to its learning curve, hemodynamic performance, and durability compared with a stented bioprosthesis. Methods and Results From January 2007 to January 2016, 776 patients underwent an Ozaki procedure at Toho University Ohashi Medical Center. Learning curves, aortic regurgitation (AR), and peak gradient, assessed by serial echocardiograms, valve rereplacement, and survival were investigated. Valve performance and durability were compared with 627 1:1 propensity‐matched patients receiving stented bovine pericardial valves implanted from 1982 to 2011 at Cleveland Clinic. Learning curves were observed for aortic clamp and cardiopulmonary bypass times, AR prevalence, and early mortality. Decreased aortic clamp time was observed over the first 300 cases. New surgeons performing parts of the procedure after case 400 resulted in a slight increase in aortic clamp and cardiopulmonary bypass times. Among matched patients, the Ozaki cohort had more AR than the PERIMOUNT cohort (severe AR at 1 and 6 years, 0.58% and 3.6% versus 0.45% and 1.0%, respectively; P [trend]=0.006), although with a steep learning curve. Peak gradient showed the opposite trend: 14 and 17 mm Hg for Ozaki and 24 and 28 mm Hg for PERIMOUNT at these times ( P [trend] < 0.001). Freedom from rereplacement was similar ( P =0.491). Survival of the Ozaki cohort was 85% at 6 years. Conclusions Patients undergoing the Ozaki procedure had lower gradients but more recurrent AR than those receiving PERIMOUNT bioprostheses. Although recurrent AR is concerning, results confirm low risk and good midterm performance of the Ozaki procedure, supporting its continued use.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3