Noninvasive Detection of Steno-Occlusive Disease of the Supra-Aortic Arteries With Three-Dimensional Contrast-Enhanced Magnetic Resonance Angiography

Author:

Willinek Winfried A.1,von Falkenhausen Marcus1,Born Markus1,Gieseke Jürgen1,Höller Tobias1,Klockgether Thomas1,Textor Hans J.1,Schild Hans H.1,Urbach Horst1

Affiliation:

1. From the Department of Radiology (W.A.W., M.v.F., M.B., J.G., H.J.T., H.H.S., H.U.), Institute of Medical Biometrics, Informatics, and Epidemiology (T.H.), and the Department of Neurology (T.K.), University of Bonn, Germany.

Abstract

Background and Purpose— Concomitant disease of the supra-aortic arteries can influence the outcome of surgical treatment of carotid artery stenosis. However, sensitivity and specificity data of noninvasive contrast-enhanced 3-dimensional (3D) magnetic resonance angiography (CE MRA) for the detection of steno-occlusive disease of the entire supra-aortic arteries including the circle of Willis remain unclear. We aimed to intra-individually compare high-spatial-resolution CE 3D MRA and digital subtraction angiography (DSA) for the assessment of steno-occlusive vascular disease of the supra-aortic arteries. Methods— CE MRA and DSA of the supra-aortic arteries were prospectively performed in 50 consecutive patients. Intra-individual comparison of CE MRA and DSA was available in 833 arteries. High-spatial-resolution CE MRA comprised a measured voxel size of 0.81 mm × 0.81 mm × 1 mm (0.66 mm 3 ). Steno-occlusive vascular disease of the 833 arteries was assessed independently by 2 radiologists according to the NASCET criteria. Results— CE MRA had a sensitivity of 100% (73/73), a specificity of 99.3% (760/765), a positive predictive value of 93.6% (73/78), and a negative predictive value of 100% (760/760) by using a 70% to 99% threshold of arterial diameter stenosis. For detection of occlusion, sensitivity, specificity, PPV, and NPV value of CE MRA were 100%, respectively. Conclusions— Noninvasive high-spatial-resolution CE MRA is suited to replace diagnostic DSA for the detection of steno-occlusive disease of the supra-aortic arteries.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3