Comparison of Ischemic Lesion Evolution in Embolic Versus Mechanical Middle Cerebral Artery Occlusion in Sprague Dawley Rats Using Diffusion and Perfusion Imaging

Author:

Henninger Nils1,Sicard Kenneth M.1,Schmidt Karl F.1,Bardutzky Jürgen1,Fisher Marc1

Affiliation:

1. From the Department of Neurology (N.H., M.F.) and Center for Comparative Neuroimaging, Department of Psychiatry (K.M.S., K.F.S.), University of Massachusetts Medical School, Worcester; and Department of Neurology (J.B.), University of Erlangen-Nuremberg, Germany.

Abstract

Background and Purpose— Differences among models in the temporal evolution of ischemia after middle cerebral artery occlusion (MCAO) in rats may considerably influence the results of experimental stroke research. Using diffusion and perfusion imaging, we compared the spatiotemporal evolution of ischemia in Sprague Dawley rats after permanent suture MCAO (sMCAO; n=8) and embolic MCAO (eMCAO; n=8). Methods— Serial measurements of quantitative cerebral blood flow (CBF) and the apparent diffusion coefficient (ADC) were performed up to 180 minutes after MCAO. ADC and CBF values within 5 different brain regions were analyzed. ADC and CBF lesion volumes were calculated by using previously established viability thresholds and correlated with infarct volume defined by 2,3,5-triphenyltetrazolium chloride staining 24 hours after MCAO. Results— Compared with sMCAO animals, the threshold-derived CBF lesion volume was significantly larger in eMCAO at all time points ( P <0.01), remained relatively constant over time, and was highly correlated with the 2,3,5-triphenyltetrazolium chloride–defined infarct size. The ADC lesion volume did not differ between models at any time point. A diffusion/perfusion mismatch was present significantly longer in eMCAO animals ( P <0.05), and these rats demonstrated larger absolute mismatch volumes that were statistically significant at 30, 60, and 90 minutes ( P <0.05). In both models, CBF and ADC declines were highly correlated. Conclusion— This study demonstrated substantial differences in acute ischemic lesion evolution between the eMCAO and sMCAO models.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3