Assessment of left ventricular and aortic valve function after aortic balloon valvuloplasty in adult patients with critical aortic stenosis.

Author:

McKay R G,Safian R D,Lock J E,Diver D J,Berman A D,Warren S E,Come P C,Baim D S,Mandell V E,Royal H D

Abstract

Preliminary reports have documented the utility of balloon aortic valvuloplasty as a palliative treatment for high-risk patients with critical aortic stenosis, but the effect of this procedure on cardiac performance has not been studied in detail. Accordingly, 32 patients (mean age 79 years) with long-standing, calcific aortic stenosis were treated at the time of cardiac catheterization with balloon dilatation of the aortic valve, and serial changes in left ventricular and valvular function were followed before and after valvuloplasty by radionuclide ventriculography, determination of systolic time intervals, and Doppler echocardiography. Prevalvuloplasty examination revealed heavily calcified aortic valves in all patients, a mean peak-to-peak aortic valve gradient of 77 +/- 27 mm Hg, a mean Fick cardiac output of 4.6 +/- 1.4 liters/min, and a mean calculated aortic valve area of 0.6 +/- 0.2 cm2. Subsequent balloon dilatation with 12 to 23 mm valvuloplasty balloons resulted in a fall in aortic valve gradient to 39 +/- 15 mm Hg, an increase in cardiac output to 5.2 +/- 1.8 liters/min, and an increase in calculated aortic valve area to 0.9 +/- 0.3 cm2. Individual hemodynamic responses varied considerably, with some patients showing major increases in valve area, while others demonstrated only small increases. In no case was balloon dilatation accompanied by evidence of embolic phenomena. Supravalvular aortography obtained in 13 patients demonstrated no or a mild (less than or equal to 1+) increase in aortic insufficiency. Serial radionuclide ventriculography in patients with a depressed left ventricular ejection fraction (i.e., that less than or equal to 55%) revealed a small increase in ejection fraction from 40 +/- 13% to 46 +/- 12% (p less than .03). In addition, for the study group as a whole there was a decrease in left ventricular end-diastolic volume index (113 +/- 38 to 101 +/- 37 ml/m2, p less than .003), a fall in stroke-volume ratio (1.49 +/- 0.44 to 1.35 +/- 0.33, p less than .04), and no immediate change in left ventricular peak filling rate (2.05 +/- 0.77 to 2.21 +/- 0.65 end-diastolic counts/sec, p = NS). Serial M mode echocardiography and phonocardiography showed an increase in aortic valve excursion (0.5 +/- 0.2 to 0.8 +/- 0.2 cm, p less than .001), a decrease in time to one-half carotid upstroke (80 +/- 30 to 60 +/- 10 msec, p less than .001), and a small decrease in left ventricular ejection time (0.44 +/- 0.03 to 0.42 +/- 0.02 sec, p less than .001).(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference16 articles.

1. Outcome of aortic valve surgery;Rahimtoola SH;Circulation,1980

2. Severe aortic stenosis with impaired left ventricular function and clinical heart failure: results of valve replacement.

3. Balloon dilatation of calcific aortic stenosis in elderly patients: postmortem, intraoperative, and percutaneous valvuloplasty studies.

4. PERCUTANEOUS TRANSLUMINAL VALVULOPLASTY OF ACQUIRED AORTIC STENOSIS IN ELDERLY PATIENTS: AN ALTERNATIVE TO VALVE REPLACEMENT?

5. Carabello BA Grossman W: Calculation of stenotic valve orifice area. In Grossman W editor: Cardiac catheterization and angiography ed 3. Philadelphia 1986 Lea and Febiger pp 143-145

Cited by 127 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3