Balloon dilatation of calcific aortic stenosis in elderly patients: postmortem, intraoperative, and percutaneous valvuloplasty studies.

Author:

McKay R G,Safian R D,Lock J E,Mandell V S,Thurer R L,Schnitt S J,Grossman W

Abstract

To assess the safety and efficacy of percutaneous balloon valvuloplasty in calcific aortic stenosis, balloon dilatation of critically stenosed, calcified aortic valves was performed in five postmortem hearts, in five patients intraoperatively before aortic valve replacement, and in two elderly patients percutaneously at the time of diagnostic catheterization. The etiology of aortic stenosis in the 12 cases was rheumatic in two, congenital bicuspid calcific stenosis in one, and senile calcific degenerative stenosis in the remaining nine. Prevalvuloplasty examination in the 10 postmortem and intraoperative cases revealed rigid valve leaflets with commissural fusion in three valves and extensive nodular calcification in seven. Subsequent balloon dilatation with 15 to 18 mm valvuloplasty balloons resulted in decreased cusp rigidity and increased mobility of valve leaflets in all cases, without evidence of tearing of valve leaflets, disruption of the valvular ring, or liberation of calcific or valvular debris. In the three valve specimens with commissural fusion, balloon dilatation resulted in partial or complete separation of leaflets along fused commissures. In two cases with extensive nodular calcification, balloon dilatation resulted in a fracture of a calcified leaflet that was evident on both gross and radiologic examination. After postmortem and intraoperative studies, percutaneous catheter valvuloplasty was performed at the time of diagnostic catheterization in two elderly patients (93- and 85-year-old women) with long-standing calcific aortic stenosis. Balloon dilatation with 12 to 18 mm balloons resulted in significant decreases in aortic gradients and significant increases in cardiac index and aortic valve area in both patients. Percutaneous valvuloplasty in both patients resulted in a mild increase in aortic insufficiency and no evidence of embolic phenomena.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 234 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3