Continuous-wave Doppler velocities and gradients across fixed tunnel obstructions: studies in vitro and in vivo.

Author:

Yoganathan A P,Valdes-Cruz L M,Schmidt-Dohna J,Jimoh A,Berry C,Tamura T,Sahn D J

Abstract

The simplified Bernoulli relationship appears to be quite accurate for predicting gradients across discrete valvular obstructions. Controversy exists about how accurately it predicts the severity of disease in longer segment obstructions. In this study we constructed a pulsatile model of subvalvular pulmonary stensosis in vitro to study nine custom-made subvalvular tunnels 2, 4, and 7 mm in length with flow cross sections of 0.5 to 1.5 cm2 and with the stenotic segment proximal to a nonstenotic bioprosthetic valve, and a pulsatile model in vitro of a 16 mm long tunnel-like ventricular septal defect (VSD) of varying cross-sectional area (0.20 to 0.64 cm2). We also compared the observations in vitro with those in an open-chest dog preparation with a tunnel-like interventricular communication. In the subpulmonic stenosis model, for each individual tunnel, 10 instantaneous peak gradients between 15 to 105 mm Hg were available. The pressure gradients across the tunnel alone, measured in the subvalvular area, were consistently higher than the measured gradients across the tunnel plus valve, suggesting some relaminarization of flow (i.e., a decrease in velocity) and pressure recovery (i.e., an increase in pressure) distal to the obstruction. Continuous-wave Doppler velocities across the 4 and 7 mm tunnels for the highest gradients were slightly lower than for the 2 mm tunnel at the same gradients, and it was only for the 0.5 cm2 cross section, 4 and 7 mm tunnels that there was a suggestion of minor viscous energy loss. For all the subvalvular tunnels studied, the Bernoulli relationship accurately predicted the results of the pressure drop across the tunnel only, while the gradient across tunnel plus valve was consistently lower. For the VSD tunnel model in vitro, the Doppler-derived gradients were approximately 40% higher than the measured gradients. The findings for the subvalvular and VSD tunnels in vitro and similar findings in the open-chest dogs with VSD suggest that relaminarization of flow and recovery of pressure occurred distal to the tunnel orifice, whereas continuous-wave Doppler findings correlate with the highest instantaneous gradients measured in the lowest pressure areas at the vena contracta of the tunnel.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 66 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3