Sequence of mitral valve motion and transmitral blood flow during manual cardiopulmonary resuscitation in dogs.

Author:

Feneley M P,Maier G W,Gaynor J W,Gall S A,Kisslo J A,Davis J W,Rankin J S

Abstract

According to the thoracic pump model of cardiopulmonary resuscitation (CPR), the heart serves as a passive conduit for blood flow from the pulmonary to the systemic vasculature, necessitating an open mitral valve and anterograde transmitral blood flow during chest compression. To assess the applicability of this model to manual CPR techniques, two-dimensional echocardiograms were recorded from the right chest wall and/or the esophagus in nine dogs (18 to 26 kg) during manual CPR. The aortic valve opened with chest compression and closed with release, while the pulmonary and tricuspid valve leaflets closed with compression and opened during release. The mitral valve remained open during ventilation alone and during abdominal compressions. With the onset of brief, high-velocity (high-impulse) chest compressions, the mitral valve closed rapidly and the left ventricle was deformed, whether compressions were applied to the sternum or the left mid-chest wall. The mitral valve reopened with release of each compression. Left atrial echocardiographic contrast injections confirmed the absence of anterograde transmitral blood flow during high-impulse compression and its presence during release. Failure of mitral leaflet approximation during chest compression was observed only when a very low-velocity, prolonged (low-impulse) compression technique was used, or when regions that did not directly overlie the heart were compressed. Consistent with these observations, simultaneous recordings of the left ventricular and left atrial pressures during high-impulse sternal compressions in five dogs (19 to 25 kg) demonstrated peak and mean left ventriculoatrial pressure gradients of 38.5 +/- 4.0 and 13.5 +/- 2.9 mm Hg, respectively, and these pressure gradients declined with less impulsive compressions. The observations made during all but low-impulse chest compressions are inconsistent with the thoracic pump model, and support direct cardiac compression as the primary mechanism of forward blood flow with more impulsive manual chest compression techniques.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 83 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3