Heparin and Air Filters Reduce Embolic Events Caused by Intra-Arterial Cerebral Angiography

Author:

Bendszus Martin1,Koltzenburg Martin1,Bartsch Andreas J.1,Goldbrunner Roland1,Günthner-Lengsfeld Thomas1,Weilbach Franz X.1,Roosen Klaus1,Toyka Klaus V.1,Solymosi László1

Affiliation:

1. From the Departments of Neuroradiology (M.B., A.J.B., T.G.-L., L.S.), Neurology (M.K., F.X.W., K.V.T.), and Neurosurgery (R.G., K.R.), University of Würzburg, Würzburg, Germany.

Abstract

Background— Intra-arterial cerebral angiography is associated with a low risk for neurological complications, but clinically silent ischemic events after angiography have been seen in a substantial number of patients. Methods and Results— In a prospective study, diffusion-weighted magnetic resonance imaging (DW-MRI) before and after intra-arterial cerebral angiography and transcranial Doppler sonography during angiography were used to evaluate the frequency of cerebral embolism. One hundred fifty diagnostic cerebral angiographies were randomized into 50 procedures, each using conventional angiographic technique, or systemic heparin treatment throughout the procedure, or air filters between the catheter and both the contrast medium syringe and the catheter flushing. There was no neurological complication during or after angiography. Overall, DW-MRI revealed 26 new ischemic lesions in 17 patients (11%). In the control group, 11 patients showed a total of 18 lesions. In the heparin group, 3 patients showed a total of 4 lesions. In the air filter group, 3 patients exhibited a total of 4 lesions. The reduced incidence of ischemic events in the heparin and air filter groups compared with the control group was significantly different ( P =0.002). Transcranial Doppler sonography demonstrated a large number of microembolic signals that was significantly lower in the air filter group compared with the heparin and control groups ( P <0.01), which did not differ from each other. Conclusions— Air filters and heparin both reduce the incidence of silent ischemic events detected by DW-MRI after intra-arterial cerebral angiography and can potentially lower clinically overt ischemic complications. This may apply to any intra-arterial angiographic procedure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3