Abstract
AbstractUniaxial Plastic Deformation (UPD) has been known to produce anomalies in residual stress measurements based on x-ray diffraction techniques. This study was undertaken to determine the magnitude of the effects, if any, on residual stress calculations from various materials subjected to UPD. An x-ray diffraction study using the two-exposure method ( ψ = 0° and ψ = U5°) was made on several iron, aluminum, and titanium alloys (AISI 4340, 4330M, 4130; 2024-13, 7075-T611; Ti-6Al-4V) before and after these alloys were deformed plastically by bending on a U-bend test fixture. The x-ray peak shifts, Δ2θ0-ψ, were recorded and the x-ray stress factors, Ki, calculated by three different methods. The results indicate that UPD of the calibration specimens will increase or decrease Ki depending on the alloy. These results are discussed together with observations on the additivity of residual and applied stresses, and the per cent differences in the stress measurements based on stress factors calculated by three different methods.
Publisher
Cambridge University Press (CUP)
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献