Electro-Optical Systems for Dynamic Display of X-ray Diffraction Images

Author:

Green Robert E.

Abstract

AbstractVarious electro-optical systems have been reported which permit intensification of X-ray diffraction patterns and thus a decrease in exposure time for recording and display of the X-ray images. Prior to 1966, all such electro-optical systems incorporated a large format X-ray image intensifier of the same type as conventionally used for medical and industrial fluoroscopy. In the past four years, a number of different systems have been reported which are superior to those developed prior to 1966. These systems may be grouped into two main categories, the large format variety for Laue diffraction applications, and the small format variety for topographic applications.The purpose of the present paper is to describe the particular characteristics of both the large format and small format systems and to discuss the advantages and disadvantages associated with each type. Based on actual performance characteristics it will be shown that:1.A multiple stage image intensifier system coupled to an external fluorescent screen is the most sensitive and only truly instantaneous system; it can be used with very weak X-ray intensities, the resolution is currently limited by the external fluorescent screen to 42μ the system is extremely versatile in that it can be used both for large format recording of Laue patterns as well as for small format recording of X-ray topographe; the system has a very long lifetime since nothing is altered by X-radiation.2.An X-ray sensitive vidicon is the least sensitive; it must be used with extremely high intensity X-rays or long exposure times; the resolution is the highest at approximately 15μ and is limited by either bandwidth of the television system, the thickness of the X-ray sensitive target or the size of the electron beam at the target; due to the small size of the X-ray sensitive target the system can only be used for small format recording of X-ray topographs; the lifetime of the system is short since X-radiation causes degradation of the target.

Publisher

Cambridge University Press (CUP)

Reference30 articles.

1. Electron Optics and Signal Read-Out of High-Definition Return- Beam Vidicon Cameras;Schade;RCA Review 31,1970

2. 28. Nudelman S. , Editor, Photoelectronic Imaging Devices, Plenum Press (scheduled far publication Fall of 1970).

3. The Silicon Diode Array Camera Tube

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Real-time and stroboscopic topography;Progress in Crystal Growth and Characterization;1987-01

2. Nondestructive Materials Characterization;Materials Characterization for Systems Performance and Reliability;1986

3. Real‐time observation of x‐ray diffraction patterns with the Lixiscope;Review of Scientific Instruments;1981-07

4. Laboratory Techniques for Transmission X-Ray Topography;Characterization of Crystal Growth Defects by X-Ray Methods;1980

5. Direct Display of X-ray Topographic Images;Advances in X-ray Analysis;1977

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3