Affiliation:
1. Department of Neurosurgery, Faculty of Medicine, Zagazig University, Zagazig, Egypt.
Abstract
Background:
Transpedicular screws are extensively utilized in lumbar spine surgery. The placement of these screws is typically guided by anatomical landmarks and intraoperative fluoroscopy. Here, we utilized 2-week postoperative computed tomography (CT) studies to confirm the accuracy/inaccuracy of lumbar pedicle screw placement in 145 patients and correlated these findings with clinical outcomes.
Methods:
Over 6 months, we prospectively evaluated the location of 612 pedicle screws placed in 145 patients undergoing instrumented lumbar fusions addressing diverse pathology with instability. Routine anteroposterior and lateral plain radiographs were obtained 48 h after the surgery, while CT scans were obtained at 2 postoperative weeks (i.e., ideally these should have been performed intraoperatively or within 24–48 h of surgery).
Results:
Of the 612 screws, minor misplacement of screws (≤2 mm) was seen in 104 patients, moderate misplacement in 34 patients (2–4 mm), and severe misplacement in 7 patients (>4 mm). Notably, all the latter 7 (4.8% of the 145) patients required repeated operative intervention.
Conclusion:
Transpedicular screw insertion in the lumbar spine carries the risks of pedicle medial/lateral violation that is best confirmed on CT rather than X-rays/fluoroscopy alone. Here, we additional found 7 patients (4.8%) who with severe medial/lateral pedicle breach who warranting repeated operative intervention. In the future, CT studies should be performed intraoperatively or within 24–48 h of surgery to confirm the location of pedicle screws and rule in our out medial or lateral pedicle breaches.
Subject
Clinical Neurology,Surgery
Reference9 articles.
1. Bone graft alone versus cage with bone graft in lumbar spine interbody fusion;Abdelbary;Zagazig Univ Med J,2019
2. Neurological events due to pedicle screw malpositioning with lateral fluoroscopy-guided pedicle screw insertion;Caelers;J Neurosurg Spine,2020
3. Commentary: Utility of the O-Arm in spinal surgery;Epstein;Surg Neurol Int,2014
4. One-step minimally invasive pedicle screw instrumentation using O-Arm and stealth navigation;Kleck;Clin Spine Surg,2018
5. Accuracy of fluoroscopic guidance with the coaxial view of the pedicle for percutaneous insertion of lumbar pedicle screws and risk factors for pedicle breach;Murata;J Neurosurg Spine,2020
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献