Quantification of Cardiac Output with Phase Contrast Magnetic Resonance Imaging in Patients with Pulmonary Hypertension

Author:

Po Jose Ricardo1,Tong Matthew2,Meeran Talha3,Potluri Alekhya4,Raina Amresh5,Doyle Mark5,Biederman Robert5

Affiliation:

1. Borgess Heart Institute, Ascension Borgess Hospital, 1722 Shaffer St., Kalamazoo, Michigan, United States

2. Department of Cardiovascular Medicine, Wexner Medical Center, 410 W 10th Ave, Columbus, Ohio, United States

3. Department of Cardiology, Fortis Hospital Mulund, Mumbai, Maharashtra, India,

4. Department of Cardiology, Einstein Medical Center, 5401 Old York Road, Philadelphia, United States

5. Cardiovascular Institute, Allegheny General Hospital, 320 E North Ave., Pittsburgh, Pennsylvania, United States,

Abstract

Objective: The purpose of the study is to compare phase contrast (PC) imaging with invasive measurements of cardiac output (CO) in patients with pulmonary hypertension (PH). Materials and Methods: We analyzed 81 cases with PH who underwent cardiac magnetic resonance imaging and right heart catheterization (RHC). Measurement of CO and stroke volume (SV) by cardiac magnetic resonance (CMR) was performed by PC imaging of the proximal aorta (Ao) and pulmonary artery (Pa) and by RHC using the Fick and thermodilution (TD) methods. Results: There was good correlation in CO measurements between PC and RHC; however, there was better correlation with SV measurements; Fick-TD (r=0.85), PC-TD (Ao r=0.77, Pa r=0.79), and PC-Fick (Ao r = 0.73, Pa r = 0.78). Bland-Altman analysis of SV showed that Pa PC had slightly lower standard deviation than Ao PC; PC-Fick (Pa SD = 15.11 vs. Ao SD = 16.4 ml) and PC-TD (Pa SD = 16.99 ml vs. Ao SD = 17.4 ml) while Fick-TD had the lowest (SD = 14.4 ml). Compared to Fick, measurement of SV with Ao PC (‒4.12 ml) and Pa PC (0.22 ml) both had lower mean difference than TD (‒11.1 ml). Conclusion: Non-invasive measurement of CO and SV using PC-CMR correlates well with invasive measurement using RHC. Our study showed that PC-CMR had high accuracy and precision when compared to Fick. Among all the modalities, PC-CMR contributed the least amount of variation in measurements.

Publisher

Scientific Scholar

Subject

Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3