Preoperative simulation of a middle cerebral artery aneurysm clipping using a rotational three-dimensional digital subtraction angiography

Author:

Kimura Yuiko12,Mashiko Toshihiro1,Watanabe Eiju1,Kawai Kensuke1

Affiliation:

1. Department of Neurosurgery, Jichi Medical University, Shimotsuke, Tochigi, Tokyo, Japan

2. Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry, Kodaira, Tokyo, Japan

Abstract

Background: In recent years, young neurosurgeons have had few opportunities to gain experience with clipping surgeries. The first author was sometimes surprised that she could not predict the anatomical relationships between the aneurysm and vessels during actual surgery. This study investigated the differences between the expected and actual operative findings during clipping surgery for aneurysms of the middle cerebral artery. Methods: Medical records for 15 patients who underwent rotational three-dimensional (3D) digital subtraction angiography (3D-DSA) before the clipping surgery were analyzed after the surgery. The anatomical relationships between the aneurysm and parent arteries were defined by the intraoperative findings just before clipping. The viewing direction to obtain this definitive perspective (virtual viewing direction) was measured. The angle between this viewing direction and the coordinate axis was denoted as the “virtual angle for clipping (VAC).” Results: The VAC between the X-axis and viewing direction on the XY-plane (VAC-XY) ranged from –43° to +73° (mean, +27°), and the angle between the XY-plane and viewing direction (VAC-Z) ranged from +25° to –34° (mean, 5.5°). The difference between the VAC-XY and mean angle was significantly larger in cases with hidden branches behind the aneurysm. In these cases, the virtual viewing direction visualized the neck of the aneurysm. There is no correlation between M1 length and VAC-XY or VAC-Z discrepancy. Conclusion: 3D-DSA or 3D computed tomography angiography images visualizing the neck of the aneurysm should be obtained in combination with images obtained from the standard oblique angle.

Publisher

Scientific Scholar

Subject

Neurology (clinical),Surgery

Reference7 articles.

1. Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback;Alaraj;Neurosurgery,2015

2. Head positioning for anterior circulation aneurysms microsurgery;Chaddad-Neto;Arq Neuropsiquiatr,2014

3. Operative Neurosurgical Anatomy;Fossett,2002

4. Simulation of the surgical manipulation involved in clipping a basilar artery aneurysm: Concepts of virtual clipping.Technical note;Koyama;J Neurol Surg,2000

5. Development of three-dimensional hollow elastic model for cerebral aneurysm clipping simulation enabling rapid and low cost prototyping;Mashiko;World Neurosurg,2015

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3