Evaluation of Six Commercial Nucleic Acid Amplification Tests for Detection of Neisseria gonorrhoeae and Other Neisseria Species

Author:

Tabrizi Sepehr N.12,Unemo Magnus3,Limnios Athena E.4,Hogan Tiffany R.4,Hjelmevoll Stig-Ove5,Garland Susanne M.12,Tapsall John4

Affiliation:

1. Department of Microbiology and Infectious Diseases, The Royal Women's Hospital, Parkville, Victoria, Australia

2. Department of Obstetrics and Gynaecology, University of Melbourne, The Royal Women's Hospital and Murdoch Childrens Research Institute, Parkville, Victoria, Australia

3. National Reference Laboratory for Pathogenic Neisseria, Department of Laboratory Medicine, Microbiology, Örebro University Hospital, Örebro, Sweden

4. WHO Collaborating Centre for STD, Microbiology Department, The Prince of Wales Hospital, Randwick, Sydney, Australia

5. Department of Microbiology and Infection Control, University Hospital of North Norway, Tromsø, Norway

Abstract

ABSTRACT Molecular detection of Neisseria gonorrhoeae in extragenital samples may result in false-positive results due to cross-reaction with commensal Neisseria species or Neisseria meningitidis . This study examined 450 characterized clinical culture isolates, comprising 216 N. gonorrhoeae isolates and 234 isolates of nongonococcal Neisseria species ( n = 218) and 16 isolates of other closely related bacteria, with six commercial nucleic acid amplification tests (NAATs). The six NAATs tested were Gen-Probe APTIMA COMBO 2 and APTIMA GC, Roche COBAS Amplicor CT/NG and COBAS 4800 CT/NG tests, BD ProbeTec GC Qx amplified DNA assay, and Abbott RealTime CT/NG test. All assays except COBAS Amplicor CT/NG test where four (1.9%) isolates were not detected showed a positive result with all N. gonorrhoeae isolates ( n = 216). Among the 234 nongonococcal isolates examined, initial results from all assays displayed some false-positive results due to cross-reactions. Specifically, the COBAS Amplicor and ProbeTec tests showed the highest number of false-positive results, detecting 33 (14.1%) and 26 (11%) nongonococcal Neisseria isolates, respectively. On the first testing, APTIMA COMBO 2, APTIMA GC, Abbott RealTime, and Roche COBAS 4800 showed lower level of cross-reactions with five (2.1%), four (1.7%), two (1%), and two (1%) of the isolates showing low-level positivity, respectively. Upon retesting of these nine nongonococcal isolates using freshly cultured colonies, none were positive by the APTIMA COMBO 2, Abbott RealTime, or COBAS 4800 test. In conclusion, the COBAS Amplicor and ProbeTec tests displayed high number of false-positive results, while the remaining NAATs showed only sporadic low-level false-positive results. Supplementary testing for confirmation of N. gonorrhoeae NAATs remains recommended with all samples tested, in particular those from extragenital sites.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3