Comparison of efficacy and cost-effectiveness of BIOMIC VIDEO and Vitek antimicrobial susceptibility test systems for use in the clinical microbiology laboratory

Author:

Berke I1,Tierno P M1

Affiliation:

1. Department of Microbiology and Pathology, New York University Medical Center, New York 10016, USA.

Abstract

Antimicrobial susceptibility testing expense may be a significant portion of a clinical microbiology laboratory's budget. This study compares the BIOMIC VIDEO system (Giles Scientific, Inc., New York, N.Y.) with the Vitek system (bioMérieux Vitek, Inc., Hazelwood, Mo.), an established automated method of antimicrobial susceptibility testing with the ability to generate MIC data. The BIOMIC system is relatively inexpensive and automates the reading of the classical disk agar diffusion test to provide both qualitative (susceptibility interpretation) and quantitative (MIC) data. The overall MIC correlation between the two systems for the 2,913 drug-organism combinations tested was 92.6%. The overall agreement for susceptibility interpretation was 97.4%. The BIOMIC system offers a 57.4% savings per test over the Vitek system. The BIOMIC system utilizes an older technology which is more efficient and yet yields results comparable to those of established automated MIC methods. The savings achievable in laboratories and hospitals nationwide may contribute significantly to the containment of national health care expenditures.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference11 articles.

1. Rapid antimicrobial susceptibility testing of gram-negative clinical isolates with the AutoMicrobic system;Backes B. A.;J. Clin. Microbiol.,1984

2. Barry A. L. 1976. The antimicrobic susceptibility test: principles and practices p. 196-207. Lea and Febiger Philadelphia.

3. Piperacillin susceptibility tests by the single-disk agar diffusion technique;Barry A. L.;Antimicrob. Agents Chemother.,1979

4. Antibiotic susceptibility testing by a standardized single disk method;Bauer A. W.;Am. J. Clin. Pathol.,1966

5. Evaluation of the BIOGRAM antimicrobial susceptibility test system;D'Amato R.;J. Clin. Microbiol.,1985

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3