Affiliation:
1. Norwegian Defence Research Establishment, Kjeller, Norway
Abstract
ABSTRACT
The ability to perform controlled experiments with bioaerosols is a fundamental enabler of many bioaerosol research disciplines. A practical alternative to using hazardous biothreat agents, e.g., for detection equipment development and testing, involves using appropriate model organisms (simulants). Several species of Gram-negative bacteria have been used or proposed as biothreat simulants. However, the appropriateness of different bacterial genera, species, and strains as simulants is still debated. Here, we report aerobiological stability characteristics of four species of Gram-negative bacteria (
Pantoea agglomerans
,
Serratia marcescens
,
Escherichia coli
, and
Xanthomonas arboricola
) in single-cell particles and cell clusters produced using four spray liquids (H
2
O, phosphate-buffered saline[PBS], spent culture medium[SCM], and a SCM-PBS mixture).
E. coli
showed higher stability in cell clusters from all spray liquids than the other species, but it showed similar or lower stability in single-cell particles. The overall stability was higher in cell clusters than in single-cell particles. The highest overall stability was observed for bioaerosols produced using SCM-containing spray liquids. A key finding was the observation that stability differences caused by particle size or compositional changes frequently followed species-specific patterns. The results highlight how even moderate changes to one experimental parameter, e.g., bacterial species, spray liquid, or particle size, can strongly affect the aerobiological stability of Gram-negative bacteria. Taken together, the results highlight the importance of careful and informed selection of Gram-negative bacterial biothreat simulants and also the accompanying particle size and composition. The outcome of this work contributes to improved selection of simulants, spray liquids, and particle size for use in bioaerosol research.
IMPORTANCE
The outcome of this work contributes to improved selection of simulants, spray liquids, and particle size for use in bioaerosol research. Taken together, the results highlight the importance of careful and informed selection of Gram-negative bacterial biothreat simulants and also the accompanying particle size and composition. The results highlight how even moderate changes to one experimental parameter, e.g., bacterial species, spray liquid, or particle size, can strongly affect the aerobiological stability of Gram-negative bacteria. A key finding was the observation that stability differences caused by particle size or compositional changes frequently followed species-specific patterns.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference50 articles.
1. National Research Council. 2005. Sensor systems for biological agent attacks: protecting buildings and military bases. Committee on Materials and Manufacturing Processing for Advanced Sensors. The National Research Council of the National Academies, The National Academic Press, Washington, DC.
2. Biological Aerosols
3. Bioaerosol health effects and exposure assessment: progress and prospects;Douwes J;Ann Occup Hyg,2003
4. Genomic Signatures of Strain Selection and Enhancement in Bacillus atrophaeus var. globigii, a Historical Biowarfare Simulant
5. National Research Council. 2008. A framework for assessing the health hazard posed by bioaerosols. Committee on Determining a Standard Unit of Measure for Biological Aerosols. The National Research Council of the National Academies, The National Academies Press, Washington, DC.