Comparison of the APTIMA CT and GC Assays with the APTIMA Combo 2 Assay, the Abbott LCx Assay, and Direct Fluorescent-Antibody and Culture Assays for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae

Author:

Boyadzhyan B.1,Yashina T.1,Yatabe J. H.1,Patnaik M.1,Hill C. S.2

Affiliation:

1. Specialty Laboratories, Inc., Santa Monica

2. Gen-Probe Incorporated, San Diego, California

Abstract

ABSTRACT The Gen-Probe APTIMA Combo 2 (AC2) is a Food and Drug Administration-cleared nucleic acid amplification test (NAAT) for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae from urine and urogenital swab specimens. The Centers for Disease Control and Prevention have recommended confirmation of positive NAAT results in low-prevalence populations. APTIMA CT (ACT) and APTIMA GC (AGC) are two discrete NAATs for C. trachomatis and N. gonorrhoeae detection that are suitable for confirming AC2-positive results because they target different nucleic acid sequences. Our objective was to determine if ACT and AGC could be used as confirmatory tests for AC2 and to correlate the APTIMA assays with culture, direct fluorescent-antibody (DFA), and LCx CT and GC assays. Urine and swab specimens (1,304) were initially tested with either culture, DFA, or LCx, followed by AC2. A subset (675) was then tested with ACT and AGC. There was absolute concordance between ACT-AGC and AC2. LCx did not detect 1 of 14 AC2-ACT- and 1 of 6 AC2-AGC-positive urine samples, and it yielded one C. trachomatis - and one N. gonorrhoeae -positive swab result that were not detected by AC2 and ACT-AGC. Culture failed to detect 5 of 20 AC2-ACT and 3 of 4 AC2-AGC positives, and DFA missed 4 of 4 AC2-ACT positives. Thus, ACT and AGC relative sensitivity compared to that of AC2 was 100%. All APTIMA assays detected more confirmed positive results than culture, DFA, and LCx. The performance of APTIMA assays was not altered by the use of various swab types and by long-term storage of specimens. All APTIMA assays are highly sensitive and rapid. ACT and AGC can be recommended for confirmation of positive results from other NAATs, such as AC2 and LCx.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3