Multicenter Studies of Tigecycline Disk Diffusion Susceptibility Results for Acinetobacter spp

Author:

Jones Ronald N.12,Ferraro Mary Jane3,Reller L. Barth4,Schreckenberger Paul C.5,Swenson Jana M.6,Sader Helio S.1

Affiliation:

1. JMI Laboratories, North Liberty, Iowa

2. Tufts University School of Medicine, Boston, Massachusetts

3. Massachusetts General Hospital, Boston, Massachusetts

4. Duke University Medical Center, Durham, North Carolina

5. Loyola University Medical Center, Maywood, Illinois

6. Centers for Disease Control and Prevention, Atlanta, Georgia

Abstract

ABSTRACT Acinetobacter sp. isolates having multidrug resistance (MDR) patterns have become common in many medical centers worldwide, limiting therapeutic options. A five-center study tested 103 contemporary clinical Acinetobacter spp., including MDR strains, by reference broth microdilution and disk diffusion (15-μg disk content) methods against tigecycline. Applying U.S. Food and Drug Administration tigecycline breakpoint criteria for Enterobacteriaceae (susceptibility at ≤2 μg/ml [≤1 μg/ml by the European Committee on Antimicrobial Susceptibility Testing]; disk diffusion breakpoints at ≥19 mm and ≤14 mm) to Acinetobacter spp. led to an unacceptable error rate (23.3%). However, an adjustment of tigecycline disk diffusion breakpoints (susceptible/resistant) to ≥16/≤12 mm reduced intermethod errors to an acceptable level (only 9.7%, all minor).

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference28 articles.

1. Aronson, N. E., J. W. Sanders, and K. A. Moran. 2006. In harm's way: infections in deployed American military forces. Clin. Infect. Dis.43:1045-1051.

2. Bradford, P. A. 2004. Tigecycline: a first in class glycycycline. Clin. Microbiol. Newsl.26:163-168.

3. Clinical and Laboratory Standards Institute. 2006. Performance standards for antimicrobial disk susceptibility tests; approved standard M2-A9 9th ed. CLSI Wayne PA.

4. Clinical and Laboratory Standards Institute. 2006. Methods for dilution antimicrobial susceptibility tests for bacteria that grow aerobically; approved standard M7-A7 7th ed. CLSI Wayne PA.

5. Clinical and Laboratory Standards Institute. 2006. Performance standards for antimicrobial susceptibility testing; M100-S16 16th informational supplement. CLSI Wayne PA.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3