Affiliation:
1. Environmental Science and Technology Institute, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
Abstract
ABSTRACT
Health risks posed by waterborne viruses are difficult to assess because it is tedious or impossible to determine the infectivity of many viruses. Recent studies hypothesized that quantitative PCR (qPCR) could selectively quantify infective viruses if preceded by an enzymatic treatment (ET) to reduce confounding false-positive signals. The goal of this study was to determine if ET with qPCR (ET-qPCR) can be used to accurately quantify the infectivity of the human viral surrogate bacteriophage MS2 upon partial inactivation by three treatments (heating at 72°C, singlet oxygen, and UV radiation). Viruses were inactivated in buffered solutions and a lake water sample and assayed with culturing, qPCR, and ET-qPCR. To ensure that inactivating genome damage was fully captured, primer sets that covered the entire coding region were used. The susceptibility of different genome regions and the maximum genomic damage after each inactivating treatment were compared. We found that (i) qPCR alone caused false-positive results for all treatments, (ii) ET-qPCR significantly reduced (up to >5.2 log units) but did not eliminate the false-positive signals, and (iii) the elimination of false-positive signals differed between inactivating treatments. By assaying the whole coding region, we demonstrated that genome damage only partially accounts for virus inactivation. The possibility of achieving complete accordance between culture- and PCR-based assays is therefore called into doubt. Despite these differences, we postulate that ET-qPCR can track infectivity, given that decreases in infectivity were always accompanied by dose-dependent decreases in ET-qPCR signal. By decreasing false-positive signals, ET-qPCR improved the detection of infectivity loss relative to qPCR.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference45 articles.
1. Detection of Murine Norovirus 1 by Using Plaque Assay, Transfection Assay, and Real-Time Reverse Transcription-PCR before and after Heat Exposure
2. Use of Murine Norovirus as a Surrogate To Evaluate Resistance of Human Norovirus to Disinfectants
3. Bhattacharya, S. S., M. Kulka, K. A. Lampel, T. A. Cebula, and B. B. Goswami. 2004. Use of reverse transcription and PCR to discriminate between infectious and non-infectious hepatitis A virus. J. Virol. Methods116:181-187.
4. Blough, N. V., and R. G. Zepp. 1995. Reactive oxygen species in natural waters, p. 280-333. In C. S. Foote, J. S. Valentine, A. Greenberg, and J. F. Liebman (ed.), Active oxygen in chemistry. Blackie Academic & Professional, London, United Kingdom.
5. Bothner, B., and G. Siuzdak. 2004. Electrospray ionization of a whole virus: analyzing mass, structure, and viability. ChemBioChem5:258-260.
Cited by
156 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献