Affiliation:
1. Department of Clinical Microbiology, St. Elisabeth Hospital, Tilburg, The Netherlands.
Abstract
The newly developed fluorescent BACTEC 9000 MB system for automated culture of mycobacteria was compared with the Septi-Chek AFB system and Lowenstein-Jensen medium (LJ). A total of 2,005 clinical specimens were included in the study. Mycobacteria were isolated from 202 (10.1%) specimens, including 155 Mycobacterium tuberculosis complex isolates and 47 Mycobacteria other than M. tuberculosis isolates. Of 131 isolates detected by the BACTEC system, the Septi-Chek AFB system, or both, 120 (91.6%) were detected by the BACTEC system and 105 (80.2%) were detected by the Septi-Chek AFB system (P < 0.02). The recovery rate in the BACTEC system compared with that in the Septi-Chek AFB system was significantly higher for M. tuberculosis complex isolates (P < 0.005) and for isolates from acid-fast smear-negative specimens (P < 0.01). Of 148 isolates detected by the BACTEC system, LJ, or both, 142 (95.9%) were detected by the BACTEC system and 118 (79.9%) were detected by LJ (P < 0.001). The recovery rate in the BACTEC system compared with that on LJ was significantly higher for M. tuberculosis complex isolates (P < 0.001). The BACTEC system detected more mycobacteria from both smear-positive and smear-negative specimens than LJ. The mean times to detection of mycobacteria were 17.6 days for the BACTEC system, 26.0 days for the Septi-Chek AFB system, and 29.4 days for LJ. The BACTEC fluorescent 9000 MB system is a rapid, sensitive, and efficient method for the isolation of mycobacteria.
Publisher
American Society for Microbiology
Reference26 articles.
1. Comparison of MB-Check, BACTEC, and egg-based media for recovery of mycobacteria;Abe C.;J. Clin. Microbiol.,1992
2. Comparison of improved BACTEC and Lowenstein-Jensen media for culture of mycobacteria from clinical specimens;Anargyros P.;J. Clin. Microbiol.,1990
3. Boyle J. F. A. E. Rendo L. B. Reller Y. Hale S. Dean S. V. Juchau and G. R. Dufour. 1995. Comparison of the BACTEC fluorescent 9000 TB system and the BACTEC radiometric 460 TB system abstr. U-141 p. 142. In Abstracts of the 95th General Meeting of the American Society for Microbiology. American Society for Microbiology Washington D.C.
4. Chapin K. Clinical microscopy p. 33-51. In P. R. Murray E. J. Baron M. A. Pfaller F. C. Tenover and R. H. Yolken (ed.) Manual of clinical microbiology 6th ed. American Society for Microbiology Washington D.C.
5. Evaluation of the Roche Septi-Chek AFB system for recovery of mycobacteria;D'Amato R. F.;J. Clin. Microbiol.,1991