Affiliation:
1. Hemosystem, 45 cours Gouffé, 13006 Marseille, France
Abstract
ABSTRACT
Bacterial contamination remains one of the major risks associated with blood product transfusion. The kinetics of bacterial growth in red blood cell concentrates (RBCC) is different than otherwise due to storage at 4°C, conditions in which most bacteria do not survive. Psychrophilic bacteria such as
Yersinia enterocolitica
, however, can proliferate from a very low level of contamination to clinically significant levels at 4°C and are known to cause severe transfusion-related infections. A screening method allowing the early detection of very low levels of bacteria in RBCC would improve transfusion safety. The Scansystem method has been previously described for detection of bacteria in platelet concentrates. We present here a modification of the system for detection of low levels of bacteria in RBCC. The Scansystem RBC kit protocol requires three steps, i.e., the agglutination and selective removal of RBCs, a labeling stage during which bacteria are labeled with a DNA-specific fluorophore, and finally recovery of bacteria on the surface of a black membrane for analysis using the Scansystem. The entire procedure from sampling to result can be completed in 90 min. Both gram-negative and gram-positive bacteria in RBCC are detected with a higher sensitivity than with currently available culture-based methods. The Scansystem RBC kit is shown to be sensitive enough to identify low-level bacterial contamination in a single unit tested in a pool of up to 20 RBCC samples (detection limit of between 1 and 10 CFU/ml depending on the bacterial strain). The method therefore lends itself to incorporation into high-sample-throughput screening programs.
Publisher
American Society for Microbiology
Reference29 articles.
1. Baskurt, O. K., M. Bor-Kucukatay, O. Yalcin, H. J. Meiselman, and J. K. Armstrong. 2000. Standard aggregating media to test the “aggregability” of rat red blood cells. Clin. Hemorheol. Microcirc.22:161-166.
2. Detection of Single Cells of
Cryptococcus neoformans
in Clinical Samples by Solid-Phase Cytometry
3. Blajchman, M. A., and M. Goldman. 2001. Bacterial contamination of platelet concentrates: incidence, significance, and prevention. Semin. Hematol.38:20-26.
4. Blajchman, M. A. 2002. Incidence and significance of the bacterial contamination of blood components. Dev. Biol.108:59-67.
5. Boulton, F. E., S. T. Chapman, and T. H. Walsh. 1998. Fatal reaction to transfusion of red-cell concentrate contaminated with Serratia liquefaciens. Transfus. Med.8:15-18.
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献