Affiliation:
1. Division of Infectious Diseases, Johns Hopkins University School of Medicine, Baltimore, MD 21205-2196.
Abstract
The Genie HIV-1/HIV-2 rapid assay was compared with an enzyme-linked immunosorbent assay and Western blot (immunoblot) by using 540 serum specimens from four different populations. The Genie HIV-1/HIV-2 assay was easy to perform, required no equipment, provided visual results within 10 min, and demonstrated excellent sensitivity and specificity compared with the Western blot.
Publisher
American Society for Microbiology
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献