In Situ-Synthesized Virulence and Marker Gene Biochip for Detection of Bacterial Pathogens in Water

Author:

Miller Sarah M.1,Tourlousse Dieter M.1,Stedtfeld Robert D.1,Baushke Samuel W.1,Herzog Amanda B.1,Wick Lukas M.2,Rouillard Jean Marie3,Gulari Erdogan3,Tiedje James M.4,Hashsham Syed A.14

Affiliation:

1. Department of Civil and Environmental Engineering

2. National Center for Food Safety and Toxicology, Michigan State University, East Lansing, Michigan 48824

3. Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan 48109

4. Center for Microbial Ecology

Abstract

ABSTRACT Pathogen detection tools with high reliability are needed for various applications, including food and water safety and clinical diagnostics. In this study, we designed and validated an in situ-synthesized biochip for detection of 12 microbial pathogens, including a suite of pathogens relevant to water safety. To enhance the reliability of presence/absence calls, probes were designed for multiple virulence and marker genes (VMGs) of each pathogen, and each VMG was targeted by an average of 17 probes. Hybridization of the biochip with amplicon mixtures demonstrated that 95% of the initially designed probes behaved as predicted in terms of positive/negative signals. The probes were further validated using DNA obtained from three different types of water samples and spiked with pathogen genomic DNA at decreasing relative abundance. Excellent specificity for making presence/absence calls was observed by using a cutoff of 0.5 for the positive fraction (i.e., the fraction of probes yielding a positive signal for a given VMG). A split multiplex PCR design for simultaneous amplification of the VMGs resulted in a detection limit of between 0.1 and 0.01% relative abundance, depending on the type of pathogen and the VMG. Thermodynamic analysis of the hybridization patterns obtained with DNA from the different water samples demonstrated that probes with a hybridization Gibbs free energy of approximately −19.3 kcal/mol provided the best trade-off between sensitivity and specificity. The developed biochip may be used to detect the described bacterial pathogens in water samples when parallel and specific detection is required.

Publisher

American Society for Microbiology

Subject

Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3