Assessment by Meta-Analysis of PCR for Diagnosis of Smear-Negative Pulmonary Tuberculosis

Author:

Sarmiento Olga L.1,Weigle Kristen A.12,Alexander Janet1,Weber David J.132,Miller William C.13

Affiliation:

1. Department of Epidemiology, School of Public Health

2. Pediatrics, School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599

3. Departments of Medicine

Abstract

ABSTRACT We conducted a meta-analysis to assess the performance of PCR for the diagnosis of smear-negative pulmonary tuberculosis (SPT) and to identify factors that account for differences in the diagnostic accuracy of different studies. Studies published before February 2002 were included if sensitivity and specificity of PCR in smear-negative respiratory or gastric-aspirate specimens could be calculated. Analysis was conducted by using summary receiver operating characteristics models. Sensitivity and specificity ranged from 9 to 100% and from 25 to 100%, respectively. Fewer than 40% of the 50 studies reported results by number of patients, reported clinical characteristics of patients, or used as a reference standard combined culture and clinical criteria. Studies that included bronchial specimens showed higher accuracy than studies that evaluated only sputum specimens or included gastric aspirates. Studies that did not report that tests were applied blindly showed higher accuracy than those reporting blind testing. Increased sensitivity due to the use of DNA purification methods was associated with decreased specificity. Studies published after 1995, using Amplicor or dUTP-UNG, were associated with an increase in specificity at the expense of lower sensitivity. We concluded that PCR is not consistently accurate enough to be routinely recommended for the diagnosis of SPT. However, PCR of bronchial specimens could be useful in highly suspicious SPT cases. Studies not reporting blind testing are likely to overestimate accuracy of PCR. Future evaluation of PCR accuracy should be conducted by patient and type of respiratory specimen, blindly, by using a reference standard that combines culture and clinical criteria and addresses the issue of how patient characteristics affect PCR accuracy.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 137 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3