Evaluation of TruCount Absolute-Count Tubes for Determining CD4 and CD8 Cell Numbers in Human Immunodeficiency Virus-Positive Adults

Author:

Schnizlein-Bick Carol T.1,Spritzler John2,Wilkening Cynthia L.2,Nicholson Janet K. A.3,O'Gorman Maurice R. G.4,

Affiliation:

1. Department of Medicine/Infectious Diseases, Indiana University School of Medicine, Indianapolis, Indiana 462021;

2. Harvard School of Public Health, Boston, Massachusetts 021462;

3. Division of HIV/AIDS, National Center for Infectious Diseases, Atlanta, Georgia 303333; and

4. The Children's Memorial Hospital and Department of Pediatrics, Northwestern University Medical School, Chicago, Illinois 606144

Abstract

ABSTRACT A single-platform technology that uses an internal bead standard and three-color flow cytometry to determine CD4 and CD8 absolute counts was evaluated for reproducibility and agreement. Values obtained using TruCount absolute-count tubes were compared to those obtained using a two-color predicate methodology. Sixty specimens from human immunodeficiency virus type 1-infected donors were shipped to five laboratories. Each site also analyzed replicates of 14 human immunodeficiency virus type 1-infected local specimens at 6 h and again at 24 h. The interlaboratory variability was significantly less with TruCount (median difference in percent coefficient of variation [%CV] between the two methods was −8% and −3% for CD4 and CD8, respectively) than with the predicate method. Intralaboratory variability was smaller, with a median difference in %CV of −1% for both CD4 and CD8 with 6-h samples and −2% and −3% for CD4 and CD8, respectively, with 24-h samples. Use of TruCount for shipped samples resulted in a median CD4 count change of 7 cells (50th estimated percentile) when all laboratories and CD4 strata were combined. For on-site samples, the median CD4 count change was 10 CD4 cells for 6-h samples and 2 CD4 cells for 24-h samples. Individual site biases occurred in both directions and cancelled each other when the data were combined for all laboratories. Thus, the combined data showed a smaller change in median CD4 count than what may have occurred at an individual site. In summary, the use of TruCount decreased both the inter- and intralaboratory variability in determining absolute CD4 and CD8 counts.

Publisher

American Society for Microbiology

Subject

Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy

Reference18 articles.

1. Positive effects of combined antiretroviral therapy on CD4+ T cell homeostasis and function in advanced HIV disease.;Autran B.;Science,1997

2. Automated cell count in flow cytometry: a valuable tool to assess CD4 absolute levels in peripheral blood.;Bene M. C.;Am. J. Clin. Pathol.,1998

3. A parallel evaluation of four automated hematology analyzers.;Bentley S. A.;Am. J. Clin. Pathol.,1993

4. Recommendations for prophylaxis against Pneumocystic carinii pneumonia for adults and adolescents infected with human immunodeficiency virus.;Centers for Disease Control;Morbid. Mortal. Weekly Rep.,1992

5. Revised classification system for HIV infection and expanded surveillance case definition for AIDS among adolescents and adults.;Centers for Disease Control;Morbid. Mortal. Weekly Rep.,1992