Comparison of two rapid commercial tests with complement fixation for serologic diagnosis of Mycoplasma pneumoniae infections

Author:

Thacker W L1,Talkington D F1

Affiliation:

1. Division of Bacterial and Mycotic Diseases, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia 30333, USA.

Abstract

The complement fixation (CF) test is the current reference serologic test for the diagnosis of Mycoplasma pneumoniae infection. However, it is reported to be insensitive and nonspecific, and it is labor intensive. To determine if a faster and more sensitive diagnosis of M. pneumoniae could be obtained, we examined 50 paired serum samples from patients with suspected M. pneumoniae infection by the CF test and two commercial rapid antibody detection kits, the Remel M. pneumoniae immunoglobulin G (IgG)-IgM antibody test system (Remel, Lenexa, Kans.) and the Seradyn Color Vue M. pneumoniae IgG-IgM kit (Seradyn, Indianapolis, Ind.). The Remel test, a 5-min qualitative immunobinding assay, detected antibodies in three patient serum samples with CF titers of 32 and in all but one sample with titers of > or = 64. The Seradyn test, a 40-min qualitative agglutination test, was less sensitive than CF or Remel. The Seradyn test was positive in 68% of cases, compared with 94 and 96% of cases tested by CF or Remel, respectively. Both commercial tests are faster and less technically demanding to perform than is the CF test.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference17 articles.

1. Evaluation of Serodia Myco II particle agglutination test for detecting Mycoplasma pneumoniae antibody: comparison with ~-capture ELISA and indirect immunofluorescence;Barker C. E.;J. Clin. Pathol.,1990

2. Detection of Mycoplasma pneumoniae by using the polymerase chain reaction;Bernet C.;J. Clin. Microbiol.,1989

3. Enzyme-linked immunosorbent assay for serodiagnosis of Mycoplasma pneumoniae infections;Busolo F.;J. Clin. Microbiol.,1983

4. Casey H. L. 1965. Part II. Adaptation of LBCF method to microtechnique p. 31-34. In Standardized diagnostic complement fixation method and adaptation to micro test. Public Health Service monograph no. 74. U.S. Public Health Service Washington D.C.

5. Outbreaks of Mycoplasma pneumoniae respiratory infection-Ohio, Texas, and New York, 1993;Centers for Disease Control and Prevention.;Morbid. Mortal. Weekly Rep.,1993

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Early diagnostic value of the antimycoplasma antibody (IgM) inMycoplasma pneumoniaepneumonia: A single-center study in 2015;Allergy, Asthma & Respiratory Disease;2019

2. Mycoplasma pneumoniae from the Respiratory Tract and Beyond;Clinical Microbiology Reviews;2017-07

3. Mycoplasma;Manual of Commercial Methods in Clinical Microbiology;2016-04-01

4. Mycoplasma and Ureaplasma;Manual of Clinical Microbiology;2015-05-26

5. Mycoplasmas;Manual of Commercial Methods in Clinical Microbiology;2014-04-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3