Automated Multiplex Assay System for Simultaneous Detection of Hepatitis B Virus DNA, Hepatitis C Virus RNA, and Human Immunodeficiency Virus Type 1 RNA

Author:

Meng Q.1,Wong C.1,Rangachari A.1,Tamatsukuri S.2,Sasaki M.2,Fiss E.1,Cheng L.1,Ramankutty T.1,Clarke D.1,Yawata H.2,Sakakura Y.2,Hirose T.2,Impraim C.1

Affiliation:

1. Roche Molecular Systems, Inc., Pleasanton, California 94588,1 and

2. Roche Diagnostics, K. K., Tokyo, Japan2

Abstract

ABSTRACT We have developed an automated multiplex system for simultaneously screening hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type 1 (HIV-1) in blood donations. The assay, designated AMPLINAT MPX HBV/HCV/HIV-1 Test (AMPLINAT MPX), consists of virus extraction and target sequence-specific probe capture on specimen preparation workstation GT-X (Roche Diagnostics K.K., Tokyo, Japan) and amplification and detection by TaqMan PCR on the ABI PRISM 7700 Analyzer (Perkin-Elmer Applied Biosystems, Foster City, Calif.). An internal control (IC) is incorporated in the assay to monitor the extraction, target amplification, and detection processes. The assay yields qualitative results without discrimination of the three targets. Detection limits (95% confidence interval) are 22 to 60 copies/ml for HBV, 61 to 112 IU/ml for HCV, and 33 to 66 copies/ml for HIV-1, using a specimen input volume of 0.2 ml. The AMPLINAT MPX assay detects a broad range of genotypes or subtypes for all three viruses and has a specificity of 99.6% for all three viruses with seronegative specimens. In an evaluation of seroconversion panels, the AMPLINAT MPX assay detects HBV infection an average of 24 days before the detection of HBsAg by enzyme immunoassay. HCV RNA was detected an average of 31 days before HCV antibody. HIV-1 RNA was detected an average of 14 days before HIV-1 antibody and an average of 9 days before p24 antigen. The Japanese Red Cross has been evaluating the AMPLINAT MPX system since October 1999. The clinical performance indicates that the AMPLINAT MPX system is robust, sensitive, and reproducible, with a high percentage of valid assay runs (96.8%), a low false-positive rate (0.34%), and a low IC failure rate (0.24%).

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3