Endpoint Quaking-Induced Conversion: a Sensitive, Specific, and High-Throughput Method for Antemortem Diagnosis of Creutzfeldt-Jacob Disease

Author:

Cheng Keding12,Vendramelli Robert1,Sloan Angela1,Waitt Brooks1,Podhorodecki Lisa1,Godal Debra1,Knox J. David13

Affiliation:

1. National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada

2. Department of Human Anatomy and Cell Sciences, Faculty of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada

3. Department of Medical Microbiology, Faculty of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada

Abstract

ABSTRACT The Prion Laboratory Section of the Public Health Agency of Canada supports heath care professionals dealing with patients suspected to have Creutzfeldt-Jakob disease (CJD) by testing cerebrospinal fluid (CSF) for protein markers of CJD. To better serve Canadian diagnostic requirements, a quaking-induced conversion (QuIC)-based assay has been added to the test panel. The QuIC tests exploit the ability of disease-associated prion protein, found in the CSF of a majority of CJD patients, to convert a recombinant prion protein (rPrP) into detectable amounts of a misfolded, aggregated form of rPrP. The rPrP aggregates interact with a specific dye, causing a measurable change in the dye's fluorescence emission spectrum. Optimal test and analysis parameters were empirically determined. Taking both practical and performance considerations into account, an endpoint QuIC (EP-QuIC) configuration was chosen. EP-QuIC uses a thermo-mixer to perform the shaking necessary to produce the quaking-induced conversions. Fluorescence readings are obtained from a microwell fluorescence reader only at the beginning and the end of EP-QuIC reactions. Samples for which the relative fluorescence unit ratio between the initial and final readings represent a ≥4 increase in signal intensity in at least two of the three replicates are classified as positive. A retrospective analysis of 91 CSF samples that included 45 confirmed cases of CJD and 46 non-CJD cases was used to estimate the performance characteristics of the EP-QuIC assay. The diagnostic sensitivity and specificity of the EP-QuIC test of this set of samples were 98 and 91%, respectively.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3