Drug Coated Balloon Angioplasty in Failing AV Fistulas

Author:

Trerotola Scott O.,Lawson Jeffrey,Roy-Chaudhury Prabir,Saad Theodore F.

Abstract

BackgroundRestenosis remains a problem in hemodialysis access interventions. Paclitaxel-coated balloons have shown promise in reducing access-related restenosis in small trials. The primary hypotheses for our multicenter trial were superior effectiveness at 180 days and noninferior safety at 30 days of a drug-coated balloon compared with conventional angioplasty for treatment of dysfunctional arteriovenous fistulas.Design, setting, participants, & measurementsThis randomized trial enrolled 285 patients with dysfunctional arteriovenous fistulas at 23 centers. Grafts, central venous stenoses, thrombosed fistulas, and immature fistulas were excluded. All patients received angioplasty of the lesion responsible for access dysfunction. After successful angioplasty (≤30% residual stenosis), lesions were treated with either a paclitaxel-coated balloon or an uncoated control balloon of similar design to the drug-coated balloon. Access function during follow-up was determined per centers’ usual protocols; reintervention was clinically driven. The primary efficacy outcome assessment was done at 6 months, and the safety assessment was done within 30 days of the procedure. Prespecified secondary end points included assessment of postintervention target lesion primary patency and access circuit primary patency at 6 months.ResultsThe 180-day end point was not met with target lesion primary patency (71%±4% for the drug-coated balloon and 63%±4% for control; P=0.06), representing a difference of 8%±6% (95% confidence interval, −3% to 20%). Access circuit primary patency did not differ between groups. Interventions to maintain target lesion patency were fewer for the drug-coated balloon at 6 months (0.31 versus 0.44 per patient; P=0.03). The primary safety noninferiority end point was met and did not differ between groups (P=0.002).ConclusionsPaclitaxel-coated balloon–assisted angioplasty did not meet the primary effectiveness end point at 180 days compared with conventional angioplasty. Both arms showed equivalent safety (ClinicalTrials.gov number NCT02440022).

Publisher

American Society of Nephrology (ASN)

Subject

Transplantation,Nephrology,Critical Care and Intensive Care Medicine,Epidemiology

Reference13 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3